UPSI Digital Repository (UDRep)
|
![]() |
|
|
Abstract : Universiti Pendidikan Sultan Idris |
This work developed a selectively modified electrode for measuring the Fe(II) ions in continuous integration using voltammetry techniques. The study assessed various aspects, such as linearity, scan rate, repeatability, and real sample analysis. The experiment is performed using differential pulse voltammetry (DPV). The findings of the study indicated that the voltammetry method exhibited a regression line of y = 36.507 ln(x) + 990.73, with a correlation value of 0.9627, with an optimum scan rate of 20 mV/s and good repeatability over five times measurement. On the other hand, when comparing the results using the UV-Vis spectrophotometric technique, the regression equation was found to be y = 0.20438x − 0.06987, with a correlation value of 0.99583. Notably, the voltammetry measurement outperformed the UV-Vis method since it allowed analysis of Fe(II) at concentrations up to 6.35 × 10−4 ppm (or 1.00 × 10−11 M), while the UV-vis measurement could only analyze up to 1.5 ppm (or 2.36 × 10−5 M). Consequently, the developed technique proves to be superior to the other methods for the analysis of Fe(II). © 2024, Gadjah Mada University. All rights reserved. |
References |
Rajoria, S., Vashishtha, M., and Sangal, V.K., 2023, Heavy metal ions in wastewater: A review on detection and toxicity, Chem. Eng. Process Tech., 8 (3), 1082. Kumar, V., Bharti, P.K., Talwar, M., Tyagi, A.K., and Kumar, P., 2017, Studies on high iron content in water resources of Moradabad district (UP) India, Water Science, 31 (1), 44–51. Samanta, S., Cloete, R., Loock, J., Rossouw, R., and Roychoudhury, A.N., 2021, Determination of trace metal (Mn, Fe, Ni, Cu, Zn, Co, Cd and Pb) concentrations in seawater using single quadrupole ICP-MS: A comparison between offline and online preconcentration setups, Minerals, 11 (11), 1289. Isa, I.M., Saidin, M.I., Ahmad, M., Hashim, N., Ghani, S.A., and Suyanta, S., 2013, Development of new copper(II) ion-selective poly(vinyl chloride) membrane electrode based on 2,6-diacetylpyridine-(1R)-(-)-fenchone diazine ligand, Int. J. Electrochem. Sci., 8 (9), 11175–11185. Ganjali, M.R., Norouzi, P., Shamsolahrari, L., and Ahmadi, A., 2006, PPb level monitoring of lanthanium by a novel PCV-membrane sensor based on 4-methyl-2-hydrazinobenzothiazole, Sens. Actuators, B, 114 (2), 713–719. March, G., Nguyen, T.D., and Piro, B., 2015, Modified electrodes used for electrochemical detection of metal ions in environmental analysis, Biosensors, 5 (2), 241–275. Salinas, G., and Frontana-Uribe, B.A., 2022, Electrochemical analysis of heavy metal ions using conducting polymer interfaces, Electrochem, 3 (3), 492–506. Putra, B.R., Darusman, L.K., and Rohaeti, E., 2013, Carbon paste electrode hexadecyltrimethyl ammonium bromide modified natural zeolite for chromium(VI) detection, Indones. J. Chem., 13 (2), 122–128. Deswati, D., Suyani, H., Safni, S., Loekman, U., and Pardi, H., 2013, Simultaneous determination of cadmium, copper and lead in sea water by adsorptive stripping voltammetry in the presence of calcon as a complexing agent, Indones. J. Chem., 13 (3), 236–241. Thanh, N.M., Van Hop, N., Luyen, N.D., Phong, N.H., and Tam Toan, T.T., 2019, Simultaneous determination of Zn(II), Cd(II), Pb(II), and Cu(II) using differential pulse anodic stripping voltammetry at a bismuth film-modified electrode, Adv. Mater. Sci. Eng., 2019, 1826148. Deswati, D., Suyani, H., and Safni, S., 2012, The method development of analysis Cd, Cu, Pb and Zn in sea water by absorptive stripping voltammetry (ASV) in the presence of calcon as complexing agent, Indones. J. Chem., 12 (1), 20–27. Evtyugin, G.A., and Porfir’eva, A.V., 2021, Determination of organic compound in aqueousorganic and ispersed media using electrochemical method of analysis, J. Anal. Chem., 76 (10), 1131–1143. Madrakian, T., Haghshenas, E., and Afkhami, A., 2014, Simultaneous determination of tyrosine, acetaminophen and ascorbic acid using gold nanoparticles/multiwalled carbon nanotube/glassycarbon electrode by differential pulse voltammetric method, Sens. Actuators, B, 193, 451–460. Abd Azis, N., Isa, I.M., Hashim, N., Ahmad, M.S., Mohd Yazid, S.N.A., Saidin, M.I., Suyanta, S., Zainul, R., Ulianas, A., Mawardi, M., and Mukdasai, S., 2020, Synergistic effect of zinc/aluminiumlayered double hydroxide-carbon nanotubes paste electrode in the electrochemical response of dopamine, acetaminophen, and bisphenol A, Int. J. Electrochem. Sci., 15 (9), 9088–9107. Skoog, D.A., Holler, F.J., and Crouch, S.R., 2017, Principles of Instrumental Analysis, 7th Ed., Cengage Learning, Boston, US. |
This material may be protected under Copyright Act which governs the making of photocopies or reproductions of copyrighted materials. You may use the digitized material for private study, scholarship, or research. |