UPSI Digital Repository (UDRep)

Revolutionising pesticide detection: A high-sensitivity electrochemical sensor with CdS/g-C3N4/MWCNTs for paraquat monitoring

AVAILABLE Article 582 Views
Scan QR Code to share or view item link:

Digital Assets & Download Files
Login required to access this item.
General Information
Title
Revolutionising pesticide detection: A high-sensitivity electrochemical sensor with CdS/g-C3N4/MWCNTs for paraquat monitoring
Type
Article
Main Author
Mohamad Idris Saidin
Additional Authors
  • Illyas Md Isa
  • Mohamad Saufi Rosmi
  • Norhayati Hashim
  • Mohamad Syahrizal Ahmad
  • Siti Nur Akmar Mohd Yazid
  • Aireen Aina Bahari
Subject
Q Science (General)
ISBN
0306-7319
Language Code
eng
Bibliographic Details
Place of Production
Tanjung Malim
Publisher
Fakulti Sains & Matematik
Year of publication
2024
Notes
International Journal of Environmental Analytical Chemistry
Dissertation Note
Other
Degree Type
Others
Corporate Name
Universiti Pendidikan Sultan Idris

Abstract

Over a decade, the Malaysia National Poison Centre found that 40% of pesticide poisoning cases may be linked to excessive paraquat (PQ) in water, soil, or food, underscoring the widespread impact on public health and emphasising the importance of detecting even trace amounts of PQ residues in the environment. Thus, this study presents a novel electrochemical sensor based on multiwalled carbon nanotubes (MWCNTs) reinforced cadmium sulphide co-anchoring on graphitic carbon nitride (CdS/g-C3N4) nanocomposites for PQ detection. The CdS/g-C3N4 nanocomposite was successfully synthesised and characterised through FTIR, XRD, EDX, FESEM and TEM analysis. The modified electrode (CdS/g-C3N4/MWCNTs PE) exhibited improved electrocatalytic activity, as demonstrated by cyclic voltammetry (CV) and impedance spectroscopy. The CdS/g-C3N4/MWCNTs PE displayed a high CV peak and low Rct value which corresponded to a higher electron transfer rate, reduced charge transfer resistance and enhanced mass transport properties. The electrochemical sensor_s performance was evaluated for the detection of PQ, and it demonstrated a linear response in a range of 1.0 _M to 0.1 mM with a limit of detection of 0.14 _M. Furthermore, the sensor exhibited selectivity with a less than 16% potential interference from various organic chemicals and inorganic ions. The sensor_s applicability was tested by quantifying PQ in real water samples, showing excellent recovery percentages ranging from 98.9% to 102.0%. The developed electrochemical sensor provides a practical solution for the rapid and accurate monitoring of PQ levels in the environment. This work establishes the foundation for the development of a selective electrochemical sensor for pesticide analysis, addressing both public health and environmental concerns. _ 2024 Informa UK Limited, trading as Taylor & Francis Group.

References

W.T. Tsai, Toxicol. Environ. Chem. 95, 197-206 (2013). doi:10.1080/02772248.2012.761999.

S.E.H. Zyoud, J. Ind. Med. 61 (6), 462-470 (2018). doi:10.1002/ajim.22835.

N.A. Kamaruzaman, Y.H. Leong, M.H. Jaafar, H.R.M. Khan, N.A.A. Rani, M.F. Razali and M.I. A. Majid, BMJ Open 10 (6), 1-9 (2020). doi:10.1136/bmjopen-2019-036048.

O. Sha, B. Cui, X. Chen, H. Liu, J. Yao and Y. Zhu, Anal Methods Chem. 2020, 1-12 (2020). doi:10.1155/2020/7359582.

M. Heydarzadeh, R. Heydari and M.H. Givianrad, Int. J. Environ. Anal. Chem. 100, 1325-1335 (2020). doi:10.1080/03067319.2019.1651852.

C. Chen, Y. Huang, P. Wu, J. Pan, P. Guo and S. Liu, Food Chem. 388, 132998 (2022). doi:10. 1016/j.foodchem.2022.132998.

N. Halim, A. Kuntom, R. Shinde and K. Banerjee, Eur. J. Lipid. Sci. Technol. 121 (8), 1900092 (2019). doi:10.1002/ejlt.201900092.

A.P. Vu, T.N. Nguyen, T.T. Do, T.H. Doan, T.H. Ha, T.T. Ta, H.L. Nguyen, P.C. Hauser, T.A. H. Nguyen and T.D. Mai, J. Chromatogr. B 1060, 111-117 (2017). doi:10.1016/j.jchromb. 2017.06.010.

S. Sain, S. Roy, A. Mathur, V.M. Rajesh, D. Banerjee, B. Sarkar and S. Roy, ACS Appl. Nano Mater. 5, 17516-17525 (2022). doi:10.1021/acsanm.2c02948.

S. Ansari, M.S. Ansari, H. Devnani, S.P. Satsangee and R. Jain, Actuators B. Chem. 273, 1226-1236 (2018). doi:10.1016/j.snb.2018.06.036.

S. Ansari, M.S. Ansari, S.P. Satsangee, M.G. Alam and R. Jain, J. Nanostructure Chem. 13 (3), 361-375 (2023). doi:10.1007/s40097-022-00473-6.

S. Ansari, M.S. Ansari, S.P. Satsangee and R. Jain, J. Pharm. Anal. 11 (1), 57-67 (2021). doi:10. 1016/j.jpha.2020.03.013.

S. Ansari, M.S. Ansari, S.P. Satsangee and R. Jain, Anal. Chim. Acta. 1046, 99-109 (2019). doi:10. 1016/j.aca.2018.09.028.

A. Alaghmandfard and K. Ghandi, Nanomaterials. 12 (2), 294. (2022).Doi doi:10.3390/ nano12020294.

V.K. Perla, S.K. Ghosh and K. Mallick, Chem. Phys. Lett. 754, 137650 (2020). doi:10.1016/j.cplett. 2020.137650.

A. Mohammad, A.H. Asseri, M.I. Khan and T. Yoon, J. Electrochem. Soc. 170, 057506 (2023). doi:10.1149/1945-7111/acd1bf.

G. Nabi, N. Malik, M.B. Tahir, M. Tanveer, R. Rafique, S. Rehman, R. Yousaf and S. Akram, Int. J. Environ. Anal. Chem. 102 (19), 8503-8518 (2022). doi:10.1080/03067319.2020.1849666.

Z. Cai, J. Chen, S. Xing, D. Zheng and L. Guo, J. Hazard Mater. 416, 126195 (2021). doi:10.1016/ j.jhazmat.2021.126195.

A.K. Singh, N. Jaiswal, R.K. Gautam and I. Tiwari, J. Electroanal. Chem. 887, 115170 (2021). doi:10.1016/j.jelechem.2021.115170.

Q. Zhao, H. Zhou, W. Wu, X. Wei, S. Jiang, T. Zhou, D. Liu and Q. Lu, Electrochim. Acta. 254, 214-222 (2017). doi:10.1016/j.electacta.2017.09.114.

F. Marahel, L. Niknam, E. Pournamdari and A. Geramizadegan, J. Iran. Chem. Soc. 19 (8), 3377-3385. (2022).Doi doi:10.1007/s13738-022-02531-w.

H. Liu, Y. Zhang, Y.P. Dong and X.F. Chu, Russ. J. Electrochem. 57, 808-815 (2021). doi:10.1134/ S1023193520120125.

M.M. Rahman, Mater. Chem. Phys. 245, 122788 (2020). doi:10.1016/j.matchemphys.2020. 122788.

L. Yuting, Z. Jing and L. Donghui, Chirality. 31 (3), 174-184 (2019). doi:10.1002/chir.23045.

M.A. Tabrizi, L. Nazari and P. Acedo, Actuators B. Chem. 345, 130377 (2021). doi:10.1016/j.snb. 2021.130377.

H.B. Fang, Y. Luo, Y.Z. Zheng, W. Ma and X. Tao, Eng. Chem. Res. 55 (16), 4506-4514 (2016). doi:10.1021/acs.iecr.6b00041.

M. Hassannezhad, M. Hosseini, M.R. Ganjali and M. Arvand, Methods 11 (15), 2064-2071 (2019). doi:10.1039/C9AY00146H.

H.S. Magar, R.Y. Hassan and A. Mulchandani, Sensors 21 (19), 6578 (2021).Doi doi:10.3390/ s21196578.


Installed and configured by Bahagian Automasi, Perpustakaan Tuanku Bainun, Universiti Pendidikan Sultan Idris
If you have enquiries, kindly contact us at pustakasys@upsi.edu.my or 016-3630263. Office hours only.