UPSI Digital Repository (UDRep)
Start | FAQ | About
Menu Icon

QR Code Link :

Type :Article
Subject :Q Science (General)
ISBN :1530-437X
Main Author :Azmi Mohamed
Additional Authors :
  • Suriani Abu Bakar
  • Illyas bin Md Isa
Title :Improved low concentration water content detection in biodiesel utilizing phase shift-based capacitive method
Hits :96
Place of Production :Tanjung Malim
Publisher :Fakulti Sains & Matematik
Year of Publication :2024
Notes :IEEE Sensors Journal
Corporate Name :Universiti Pendidikan Sultan Idris
HTTP Link : Click to view web link
PDF Full Text :You have no permission to view this item.

Abstract : Universiti Pendidikan Sultan Idris
Biodiesel has become an alternative fuel to substitute conventional fuel, yet challenges remain, particularly concerning water content. The presence of water in biodiesel can negatively impact engine spray and combustion properties and may lead to damage storage tanks. To address this issue, a phase-shift-based capacitive sensor was developed in this study to accurately measure water concentration in biodiesel. The sensor, designed with a semicylindrical electrode on a glass tube, is integrated with a signal conditioning circuit and the Digilent Analog Discovery module, allowing for real-time data analysis and enhanced sensitivity in detecting low concentrations of water concentration in biodiesel. The experimental results demonstrated a direct correlation between capacitance values and phase shift, with higher capacitance leading to more significant phase shifts. A Bode plot and simulation analysis, utilizing the transfer function, validated these experimental conditions, confirming the relationship between capacitance and signal phase shift. Additionally, experiments assessing biodiesel water content revealed a proportional increase in phase-shift angle with rising water concentration, measuring water concentration in biodiesel at levels as low as 800 ppm. These findings underscore that the phase-shift magnitude in the sensor's output reliably detects low-concentration water content in biodiesel. The performance of this sensor is particularly advantageous due to its high sensitivity, enabling the detection of low water concentrations that are crucial for maintaining biodiesel quality. Moreover, the real-time data analysis capability provided by the Digilent Analog Discovery highlights the sensor's practicality and efficiency for on-the-spot monitoring, offering a significant improvement over conventional methods. 

References

M. Lapuerta, J. Sánchez-Valdepeñas, and E. Sukjit, “Effect of ambient humidity and hygroscopy on the lubricity of diesel fuels,” Wear, vol. 309, nos. 1–2, pp. 200–207, Jan. 2014, doi: 10.1016/j.wear.2013.11.017.

A. N. Ramadhani, A. Harimawan, and H. Devianto, “Water content effect on biofilm formation and bio-corrosion process in biodiesel-diesel storage tank,” Int. J. Eng. Technol., vol. 7, no. 4, pp. 2009–2012, Sep. 2018, doi: 10.14419/ijet.v7i4.15592.

C.-Y. Lin and L. Ma, “Influences of water content in feedstock oil on burning characteristics of fatty acid methyl esters,” Processes, vol. 8, no. 9, p. 1130, Sep. 2020, doi: 10.3390/pr8091130.

E. D. Christensen and R. L. McCormick, “Water contamination impacts on biodiesel antioxidants and storage stability,” Energy Fuels, vol. 37, no. 7, pp. 5179–5188, Apr. 2023, doi: 10.1021/acs.energyfuels.2c03911.

I. Celik and O. Aydin, “Effects of B100 biodiesel on injector and pump piston,” Tribol. Trans., vol. 54, no. 3, pp. 424–431, Mar. 2011, doi: 10.1080/10402004.2011.556313.

Standard Specification for Biodiesel Fuel (B100) Blend Stock for Distillate Fuels, ASTM Standard D6751-23, 2023, doi: 10.1520/D6751-23.

M. P. Vicentim, M. V. B. Sousa, V. F. da Silva, V. L. Mateus, J. M. Rodrigues, and V. S. da Cunha, “Water content determination in biodiesel: Optimization of methodology in coulometric Karl Fischer titration,” J. ASTM Int., vol. 7, no. 2, pp. 1–7, Feb. 2010, doi: 10.1520/jai102615.

P. Felizardo, P. Baptista, M. S. Uva, J. C. Menezes, and M. J. N. Correia, “Monitoring biodiesel fuel quality by near infrared spectroscopy,” J. Near Infr. Spectrosc., vol. 15, no. 2, pp. 97–105, 2007, doi: 10.3390/pr11041071.

C.-Y. Lin and L. Ma, “Influences of water content in feedstock oil on burning characteristics of fatty acid methyl esters,” Processes, vol. 8, no. 9, p. 1130, Sep. 2020, doi: 10.3390/pr8091130.

M. Demori, V. Ferrari, and D. Strazza, “A sensor system for oil fraction estimation in a two phase oil-water flow,” Proc. Chem., vol. 1, no. 1, pp. 1247–1250, Sep. 2009, doi: 10.1016/j.proche.2009.07.311.

S. C. Bera, J. K. Ray, and S. Chattopadhyay, “A low-cost noncontact capacitance-type level transducer for a conducting liquid,” IEEE Trans. Instrum. Meas., vol. 55, no. 3, pp. 778–786, Jun. 2006, doi: 10.1109/TIM.2006.873785

R. T. Bento, R. W. O. Silva, L. A. Dias, A. F. Filho, and A. J. C. Pitta, “Design, development and application of a real-time capacitive sensor for automatically measuring liquid level,” Social Netw. Appl. Sci., vol. 1, no. 7, p. 734, Jun. 2019, doi: 10.1007/s42452-019-0770-3.

A. d. N. Wrasse, E. N. dos Santos, M. J. da Silva, H. Wu, and C. Tan, “Capacitive sensors for multiphase flow measurement: A review,” IEEE Sensors J., vol. 22, no. 22, pp. 21391–21409, Nov. 2022, doi: 10.1109/JSEN.2022.3210467.

K. Mochizuki, T. Masuda, and K. Watanabe, “An interface circuit for high-accuracy signal processing of differential-capacitance transducers,” IEEE Trans. Instrum. Meas., vol. 47, no. 4, pp. 823–827, Aug. 1998.

O. Kanoun, A. Y. Kallel, and A. Fendri, “Measurement methods for capacitances in the range of 1 pF–1 nF: A review,” Measurement, vol. 195, May 2022, Art. no. 111067, doi: 10.1016/j.measurement.2022.111067.


This material may be protected under Copyright Act which governs the making of photocopies or reproductions of copyrighted materials.
You may use the digitized material for private study, scholarship, or research.

Back to search page

Installed and configured by Bahagian Automasi, Perpustakaan Tuanku Bainun, Universiti Pendidikan Sultan Idris
If you have enquiries, kindly contact us at pustakasys@upsi.edu.my or 016-3630263. Office hours only.