[1] Steven, J. C. (2016). The suitability of active personal dosimeters as the legal dosimeter for PET Radioisotope workers.An M.Sc. Dissertation submitted to school of postgraduate studies, The University of Western Australia (Unpublished) 13-19
[2] Bappah S. Yahaya, Umar Ibrahim, Samson D. Yusuf, Abdullahi A. Mundi , Mustapha M. Idris, Habib Sa’ad, Anas Mohammed & Reuben J. Soja (2019). Performance Evaluation of Thermolumniscence Dosimeters in Personnel in-Vivo Dosimetry, DUJOPAS, 5 (2): 195-203
[3] United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) (2006).Effects of Ionizing Radiation.United Nations, New York (1)
[4] Boyd, W. L. (2009). Using Thermoluminescence Dosimeters to Measure the Dose From High and Low Energy X-Ray Sources. Message posted to UNLV Theses, Dissertations, Professional Papers, and Capstones. Accessed on 11th November, 2018 from http://digitalscholarship.unlv.edu/thesesdissertations/1203
[5] International Atomic Energy Agency (IAEA) (2002). Occupational radiation protection: Protecting workers against exposure to ionizing radiation.Proceedings of an International Conference, Geneva, 26-30 August 2002
[6] International Commission on Radiological Protection (ICRP) (1990).Report 60 Recommendations of the International Commission on Radiological Protection. Publ 60, Ann ICRP 21 (1-3)
[7] Aya, M. H. A. (2018). New Trend in Radiation Dosimeters.American Journal of Modern Physics, 7(1), 21-30. https://doi.org/10.11648/j.ajmp.20180701.13
[8] Antonio, P., Pinto, T. N. O. & Caldas, L. V. E. (2010).TL and OSL techniques for calibration of 90Sr+90Y clinical applicators.Dosimetry Poster presentations, Helsinki, Finland, 4(03), 769-775
[9] Izewska, J. &Rajan, G. (2012).Radiation dosimeters. Dosimetry and Medical Radiation Physics. Message posted to IAEA. Accessed on 11th November, 2018 from: http://www.naweb.iaea.org/nahu/dmrp/pdf_files/Chapter3
[10] Singh, V.P., Managanvi, S.S., Bihari, R.R. &Bhat, H.R. (2013). Operational experience of electronic active personal dosimeter and comparison with CaSo4:Dy TL dosimeter in Indian PHWR. Radiation Protection Dosimetry, 156(1), 93–102.
[11] Seco, J., Clasie, B. & Partridge, M. (2014). Review on the characteristics of radiation detectors for dosimetry and imaging. Phys. Med. Biol., 59 (20), 303–347.https://doi:10.1088/0031-9155/59/20/R303
[12] Lummis, S. (2013). Personal Radiation Monitoring System Inefficiencies: A Comparison in Service Provision. In Proceedings of the 2013 Conference of the ACPSEM, Pan Pacific Hotel Perth, 2013, 226
[13] Garzón, W. J., Khoury, H., Ovalle, S. A. M. & Medeiros, R. B. (2018).Performance of the Instadose dosimeter for interventional radiology and cardiology application.Radiation Protection Dosimetry, 1(7), 2, https://doi.org/10.1093/rpd/ncy172
[14] Miron (2018).Instadose Dosimeter, Instant, Precise, Portable. Accessed on 8th October, 2018 from http://www.miron.com
[15] Ginjaume, M. (2011).Performance and approval procedures for active personal Dosimeters.Radiation Protection Dosimetry, 144 (1-4), 144–149, https://doi.org/10.1093/rpd/ncq457
[16] Covens, P., Berus, D., Buls N., Clerinx, P. &Vanhavere, F. (2007).Personal dose monitoring in hospitals: Global assessment, critical applications and future needs.Radiation Prot. Dosimetry, 124(3), 250-259
[17] Furetta, C. &Weng, P.S. (1997).Operational Thermoluminescence Dosimetry.World Scientific, Singapore, 3(1-2), 22-28
[18] Koguchi, Y., Yamamoto, T. & Maria R. (2010). Intercomparison of various dosimetry systems for routine individual monitoring.Dosimetry Oral presentations, Helsinki, Finland,4(19) 835
[19] Sabine, M., Markus, B. & Annette, F. S. (2010). Reproducibility assessment fora new neutron dose evaluation system.Dosimetry Poster presentations, Helsinki, Finland, 4(01), 755-758
[20] Daniel, M., Ailza, C. S., Elizaima, F. S. & Ernesto, M. H. (2000). Characteristics of a Thermoluminescence Dosimetry System based on LiF:Mg,Cu,P (GR-200) Detectors for Environmental Monitoring. Rad. Prot. Dosimetry, 60(2), 147-153
[21] Nguyen, P. D.,Takashi, M., Katsuhiro, O., Kazuichi, O. & Hiroyuki, M. (2001). Basic characteristics examination of Direct Ion Storage (DIS) dosimeter.Japan Atomic Energy Research Institute, JP0150733 047
[22] Pugliese, M., Roca, V. & Durante, M. (2010).The use of TL dosimeters in HZE radiation fields.Dosimetry Poster presentations, Helsinki, Finland, 4(19), 832-834
[23] Campos, L. L., Rocha, F. D., & Campos, V. (2010). CaSO4:Dy TL response for photons energies between 33 keV to 15 MeV. Dosimetry Poster presentations, Helsinki, Finland, 4(09), 797-798.
[24] Teixeira, M. & Caldas, L V. E. (2010).Dosimetric properties of agate stones.Dosimetry Poster presentations, Helsinki, Finland, 4(14), 811-816.
[25] Andrew, V. & Braden, G. (2019).Loss of TLD signal due to high temperature environmental conditions. Radiation Protection Dosimetry, 130 (34), 1-4, https://doi.org/10.1093/rpd/ncz130