Abollino, O., Giacomino, A., & Malandrino, M. (2018). Stripping Voltammetry. In
Encyclopedia of Analytical Science, (3rd ed., pp. 1–20). Elsevier Inc.
Abramovic, B. F., Anderluh, V. B., Šojic, D. V., & Gaál, F. F. (2007). Photocatalytic
removal of the herbicide clopyralid from water. Journal of the Serbian Chemical
Society, 72(12), 1477–1486.
Achterberg, E. P., Gledhill, M., Hawkes, J. A., & Avendano, L. C. (2013). Voltammetry
| Cathodic Stripping. Reference Module in Chemistry, Molecular Sciences and
Chemical Engineering (pp. 203-211). Elsevier Inc.
Adam, N., Mohd Ghazali, S. A. I. S., Dzulkifli, N. N., Hak, C. R. C., & Sarijo, S. H.
(2019). Intercalations and characterization of zinc/aluminium layered double
hydroxide-cinnamic acid. Bulletin of Chemical Reaction Engineering &Amp;
Catalysis, 14(1), 165–172.
Adeloju, S. B. (2007). Electrochemical stripping analysis of trace and ultra-trace
concentrations of toxic metals and metalloids in foods and beverages. In Food
Toxicants Analysis: Techniques, Strategies and Developments (pp. 667–696).
Woodhead Publishing Limited.
Adhikari, B.-R., Maduraiveeran, G., & Chen, A. (2014). Sensitive detection of
acetaminophen with graphene-based electrochemical sensor. Electrochimica Acta,
162, 198-204
Ahmad, M. S., Isa, I., Hashim, N., & Rosmi, M. S. (2018). Electrochemical detection
of hydroquinone by square wave voltammetry using a Zn layered hydroxideferulate
(ZLH-F) modified MWCNT paste electrode. International Journal of
Electrochemical Science, 13, 373–383.
Ahmad, M. S., Isa, I., Hashim, N., Si, S. M., & Saidin, M. I. (2018). A highly sensitive
sensor of paracetamol based on zinc-layered hydroxide-L-phenylalanate-modified
multiwalled carbon nanotube paste electrode. Journal of Solid State
Electrochemistry, 22(3), 2691–2701.
Ahmad, M. S., Isa, I. M., Hashim, N., Saidin, M. I., Si, S. M., Zainul, R., & Mukdasai,
S. (2019). Zinc layered hydroxide-sodium dodecyl sulphate-isoprocarb modified
multiwalled carbon nanotubes as sensor for electrochemical determination of
dopamine in alkaline medium. International Journal of Electrochemical Science,
14(9), 9080–9091.
Ahmadpour, S., Tashkhourian, J., & Hemmateenejad, B. (2020). A chemometric
investigation on the influence of the nature and concentration of supporting
electrolyte on charging currents in electrochemistry. Journal of Electroanalytical
Chemistry, 871, 114296.
Ahmed, J., Rahman, M. M., Siddiquey, I. A., Asiri, A. M., & Hasnat, M. A. (2017).
Efficient bisphenol-A detection based on the ternary metal oxide (TMO)
composite by electrochemical approaches. Electrochimica Acta, 246, 597–605.
Alderman, M. H. (2001). Serum uric acid as a cardiovascular risk factor for heart
disease. Current Hypertension Reports, 3, 184–189.
Allou, N. B., Saikia, P., Borah, A., & Goswamee, R. L. (2017). Hybrid nanocomposites
of layered double hydroxides : An update of their biological applications and
future prospects. Colloid and Polymer Science, 295(5), 725–747.
Alnaimat, A. S., Barciela-Alonso, M. C., & Bermejo-Barrera, P. (2019). Determination
of bisphenol A in tea samples by solid phase extraction and liquid chromatography
coupled to mass spectrometry. Microchemical Journal, 147, 598-604.
Alvarez-Lario, B., & Macarron-Vicente, J. (2010). Uric acid and evolution.
Rheumatology, 49, 2010–2015.
Alves, G. M. S., Rocha, L. S., & Soares, H. M. V. M. (2017). Multi-element
determination of metals and metalloids in waters and wastewaters, at trace
concentration level, using electroanalytical stripping methods with
environmentally friendly mercury free-electrodes: A review. Talanta, 175, 53-68.
Andrade-Eiroa, A., Canle, M., Leroy-Cancellieri, V., & Cerdà, V. (2015). Solid phase
extraction of organic compounds: A critical review. Trends in Analytical
Chemistry, 80, 655–667.
Anson, F. C. (1966). Innovations in the study of adsorbed reactants by
chronocoulometry. Analytical Chemistry, 38(1), 54–57.
Apetrei, C., Apetrei, I. M., Saja, J. A. De, & Rodriguez-Mendez, M. L. (2011). Carbon
paste electrodes made from different carbonaceous materials: Application in the
study of antioxidants. Sensors, 11, 1328–1344.
Apodaca, D. C., Pernites, R. B., Ponnapati, R., Del Mundo, F. R., & Advincula, R. C.
(2011). Electropolymerized molecularly imprinted polymer film: EIS sensing of
bisphenol A. Macromolecules, 44(17), 6669–6682.
Arvand, M., & Hassannezhad, M. (2014). Magnetic core-shell Fe3O4@SiO2/MWCNT
nanocomposite modified carbon paste electrode for amplified electrochemical
sensing of uric acid. Materials Science and Engineering C, 36(1), 160–167.
Asadpour-Zeynali, K., & Amini, R. (2017). Nanostructured hexacyanoferrate
intercalated Ni/Al layered double hydroxide modified electrode as a sensitive
electrochemical sensor for paracetamol determination. Electroanalysis, 29(2),
635–642.
Atta, N. F., Ali, S. M., El-ads, E. H., & Galal, A. (2013). Nano-perovskite carbon paste
composite electrode for the simultaneous determination of dopamine, ascorbic
acid and uric acid. Electrochimica Acta, 128, 16–24.
Azis, N. A., Isa, I. M., Hashim, N., Ahmad, M. S., Yazid, S. N. A. M., & Saidin, M. I.
(2019). Voltammetric determination of bisphenol A in the presence of uric acid
using a Zn/Al-LDH-QM modified MWCNT paste electrode. International
Journal of Electrochemical Science, 14, 10607-10621.
Babaei, A., Afrasiabi, M., & Azimi, G. (2015). Nanomolar simultaneous determination
of epinephrine and acetaminophen on a glassy carbon electrode coated with a
novel Mg-Al layered double hydroxide-nickel hydroxide nanoparticles-multiwalled
carbon nanotubes composite. Analytical Methods, 7(6), 2469–2478.
Baccarin, M., Santos, F. A., Vicentini, F. C., Zucolotto, V., Janegitz, B. C., & Fatibello-
Filho, O. (2017). Electrochemical sensor based on reduced graphene oxide/carbon
black/chitosan composite for the simultaneous determination of dopamine and
paracetamol concentrations in urine samples. Journal of Electroanalytical
Chemistry, 799(6), 436–443.
Baig, N., & Sajid, M. (2017). Applications of layered double hydroxides based
electrochemical sensors for determination of environmental pollutants : A review.
Trends in Environmental Analytical Chemistry, 16(10), 1–15.
Baruah, A., Mondal, S., Sahoo, L., & Gautam, U. K. (2019). Ni-Fe-layered double
hydroxide/N-doped graphene oxide nanocomposite for the highly efficient
removal of Pb(II) and Cd(II) ions from water. Journal of Solid State Chemistry,
280, 120963.
Bas, B., Bugajna, A., Jakubowska, M., Reczynski, W., & Smalec, A. (2013). The
renewable glassy carbon annular band electrode in a highly sensitive normal pulse
voltammetric determination of paracetamol with continuous wavelet
transformation. Electrochimica Acta, 99, 190–197.
Bashi, A. M., Hussein, M. Z., Zainal, Z., Rahmani, M., & Tichit, D. (2012).
Simultaneous intercalation and release of 2,4-dichloro and 4-chloro-phenoxy
acetates into Zn/Al layered double hydroxide. Arabian Journal of Chemistry, 9,
S1457–S1463.
Bayram, E., & Akyilmaz, E. (2016). Chemical development of a new microbial
biosensor based on conductive polymer/multiwalled carbon nanotube and its
application to paracetamol determination. Sensors & Actuators: B. Chemical, 233,
409–418.
Benecyo, J. E. (2016). Simultaneous Determination of BPA and BPS Using UV/ Vis
Spectrophotometry and HPLC. Ouachita Baptist University Scholarly.
Berber, M., Hafez, I., Minagawa, K., Mori, T., & Tanaka, M. (2011). Versatile
nanocomposite formulation system of non-steroidal anti-inflammatory drugs of
the arylalkanoic acids, Advances in Nanocomposite Technology, Abbass Hashim,
IntechOpen.
Bessems, J. G. M., & Vermeulen, N. P. E. (2001). Paracetamol (acetaminophen)-
induced toxicity : Molecular and biochemical mechanisms , analogues and
protective approaches. Critical Reviews in Toxicology, 31(1), 55–138.
Bhakta, A. K., Mascarenhas, R. J., D’Souza, O. J., Satpati, A. K., Detriche, S.,
Mekhalif, Z., & Dalhalle, J. (2015). Iron nanoparticles decorated multi-wall
carbon nanotubes modified carbon paste electrode as an electrochemical sensor
for the simultaneous determination of uric acid in the presence of ascorbic acid,
dopamine and L-tyrosine. Materials Science & Engineering C, 57, 328–377.
Bilal, S. (2014). Cyclic Voltammetry. In G. Kreysa, K. Ota, & R. F. Savinell (Eds.),
Encyclopedia of Applied Electrochemistry (pp. 285–289). New York, NY:
Springer New York.
Bilewicz, R., Wikiel, K., Osteryoung, R., & Osteryoung, J. (2002). General equivalence
of linear scan and staircase voltammetry : Experimental results. Analytical
Chemistry, 61(9), 965–972.
Bini, M., & Monteforte, F. (2018). Layered double hydroxides (LDHs): Versatile and
powerful hosts for different applications. Journal of Analytical & Pharmaceutical
Research, 7(1), 00206.
Bode and nyquist plot (2020). Retrieved from
https://www.palmsenscorrosion.com/knowledgebase/bode-and-nyquist-plot/
Bolat, G., Yaman, Y. T., & Abaci, S. (2018). Highly sensitive electrochemical assay
for bisphenol A detection based on poly (CTAB)/MWCNTs modified pencil
graphite electrodes. Sensors and Actuators, B: Chemical, 255, 140–148.
Bontempelli, G., Dossi, N., & Toniolo, R. (2019). Polarography/Voltammetry. In
Encyclopedia of Analytical Science, (3rd ed., pp. 218-229). Elsevier Inc.
Brede, C., Fjeldal, P., Skjevrak, I., & Herikstad, H. (2003). Increased migration levels
of bisphenol A from polycarbonate baby bottles after dishwashing , boiling and
brushing. Food Additives and Contaminants, 20(7), 684–689.
Brock, J. W., Yoshimura, Y., Barr, J. R., Maggio, V. L., Graiser, S. R., Nakazawa, H.,
& Needham, L. L. (2001). Measurement of bisphenol A levels in human urine.
Journal of Exposure Analysis and Environmental Epidemiology, 11, 323–328.
Brownson, D. A. C., & Banks, C. E. (2014). The Handbook of Graphene
Electrochemistry (1st ed.). Springer-Verlag London.
Bruna, F., Celis, R., Pavlovic, I., Barriga, C., Cornejo, J., & Ulibarri, M. A. (2009).
Layered double hydroxides as adsorbents and carriers of the herbicide (4-chloro-
2-methylphenoxy) acetic acid (MCPA): Systems Mg–Al, Mg–Fe and Mg–Al–Fe.
Journal of Hazardous Materials, 168, 1476–1481.
Bunchorntavakul, C., & Reddy, K. R. (2013). Acetaminophen-related hepatotoxicity.
Clinics in Liver Disease, 17(4), 587–607.
C. Moldoveanu, S., & David, V. (2017). Short overviews of analytical techniques not
containing an independent separation step. In Selection of the HPLC Method in
Chemical Analysis (pp. 31–53). Elsevier.
Caban, M., Lis, E., Kumirska, J., & Stepnowski, P. (2015). Environment determination
of pharmaceutical residues in drinking water in Poland using a new SPE-GC-MS
( SIM ) method based on Speedisk extraction disks and DIMETRIS derivatization.
Science of the Total Environment, 538, 402–411.
Careghini, A., Mastorgio, A. F., Saponaro, S., & Sezenna, E. (2015). Bisphenol A,
nonylphenols, benzophenones, and benzotriazoles in soils, groundwater, surface
water, sediments, and food : A review. Environmental Science and Pollution
Research, 22, 5711–5741.
Cavani, F., Trifiro, F., Vaccari, A. (1991). Hydrotalcite-type anionic clays: preparation,
properties and applications. Catalysis Today, 11, 173–301.
Chapin, R. E., Adams, J., Boekelheide, K., Gray, L. E., Hayward, S. W., Lees, P. S. J.,
et al. (2008). NTP-CERHR expert panel report on the reproductive and
developmental toxicity of bisphenol A. Birth Defects Research Part B -
Developmental and Reproductive Toxicology, 83(3), 157–395.
Cheemalapati, S., Palanisamy, S., Mani, V., & Chen, S. M. (2013). Simultaneous
electrochemical determination of dopamine and paracetamol on multiwalled
carbon nanotubes/graphene oxide nanocomposite-modified glassy carbon
electrode. Talanta, 117, 297–304.
Chen, X., Zhou, G., Mao, S., & Chen, J. (2018). Rapid detection of nutrients with
electronic sensors: A review. Environmental Science: Nano, 5, 837–862.
Chen, Z., Guo, J., Zhou, T., Zhang, Y., & Chena, L. (2013). A novel nonenzymatic
electrochemical glucose sensor modified with Ni/Al layered double hydroxide.
Electrochimica Acta, 109(3), 532–535.
Chiavazza, E., Berto, S., Giacomino, A., Malandrino, M., Barolo, C., Prenesti, E., et al
(2016). Electrocatalysis in the oxidation of acetaminophen with an
electrochemically activated glassy carbon electrode. Electrochimica Acta, 192,
139–147.
Chou, J. (1999). Hazardous gas monitors : A practical guide to selection, operation
and applications (1st ed). New York: McGraw-Hill.
Christie, J. H., & Lingane, P. J. (1965). Theory of staircase voltammetry. Journal of
Electroanalytical Chemistry, 10(3), 176–182.
Ciszewski, A., & Milczarek, G. (1999). Polyeugenol-modified platinum electrode for
selective detection of dopamine in the presence of ascorbic acid. Analytical
Chemistry, 71(5), 1055–1061.
Ciui, A. B., Tertis, M., Feurdean, C., Ilea, A., Sandulescu, R., Wang, J., et al. (2018).
Cavitas electrochemical sensor toward detection of N-epsilon
(Carboxymethyl)lysine in oral cavity. Sensors & Actuators: B. Chemical.
Concenço, G., Silva, A. F., Ferreira, E. A., Galon, L., Noldin, J. A., Aspiazú, I., et al.
(2009). Effect of dose and application site on quinclorac absorption by barnyardgrass biotypes. Planta Daninha, 27(3), 541–548.
Correia-sá, L., Norberto, S., Delerue-matos, C., Calhau, C., & Domingues, V. F. (2018).
Micro-QuEChERS extraction coupled to GC–MS for a fast determination of
bisphenol A in human urine. Journal of Chromatography B, 1072(10), 9–16.
Cosio, M. S., Pellicanò, A., Brunetti, B., & Fuenmayor, C. A. (2017). A simple
hydroxylated multi-walled carbon nanotubes modified glassy carbon electrode for
rapid amperometric detection of bisphenol A. Sensors and Actuators, B:
Chemical, 246, 673–679.
Cosio, M. S., Scampicchio, M., & Benedetti, S. (2012). Electronic noses and tongues.
In Chemical analysis of Food: Techniques and Applications (pp. 219–247).
Elsevier Inc.
Costa-rama, E., & Abedul, M. T. F. (2020). Adsorptive stripping voltammetry of indigo
blue in a flow system. In Laboratory Methods in Dynamic Electroanalysis (pp.
47–56). Elsevier Inc.
Costello, B. P. J. D. L., Evans, P., & Ratcliffet, N. M. (1996). Preparation of polypyrrole
composites and the effect of volatile amines on their electrical properties. Analyst,
121(June), 793–797.
Courade, J.-P., Caussade, F., Martin, K., Besse, D., Delchambre, C., Hanoun, N., et al.
(2001). Effects of acetaminophen on monoaminergic systems in the rat central
nervous system. Naunyn-Schmiedeberg’s Archives of Pharmacology, 364, 534–
537.
Cox, K. H., Gatewood, J. D., Howeth, C., & Rissman, E. F. (2010). Hormones and
behavior gestational exposure to bisphenol A and cross-fostering affect behaviors
in juvenile mice. Hormones and Behavior, 58(5), 754–761.
Crepaldi, E. L., Pavan, P. C., & Valim, J. B. (2000). Anion exchange in layered double
hydroxides by surfactant salt formation. Journal of Materials Chemistry, 10,
1337–1343.
D’Souza, O. J., Mascarenhas, R. J., Thomas, T., Basavaraja, B. M., Saxena, A. K.,
Mukhopadhyay, K., et al. (2015). Platinum decorated multi-walled carbon
nanotubes/Triton X-100 modified carbon paste electrode for the sensitive
amperometric determination of paracetamol. Journal of Electroanalytical
Chemistry, 739, 49–57.
Darmapatni, K. A. G., Basori, A., & Suaniti, N. M. (2016). Pengembangan metode GCMS
untuk penetapan kadar acetaminophen pada spesimen rambut manusia. Jurnal
Biosains Pascasarjana, 18(3), 58-71.
Dawei, Q., Zhang, Q., Zhou, W., Zhao, J., Zhang, B., Sha, Y., et al. (2016).
Quantification of dopamine in brain microdialysates with high- performance
liquid chromatography–tandem mass spectrometry. Analytical Sciences, 32(4),
419–424.
Dejous, C., Hallil, H., Raimbault, V., Rukkumani, R., & Yakhmi, J. V. (2017). Using
microsensors to promote the development of innovative therapeutic
nanostructures. In Nanostructures for Novel Therapy (pp. 539–566). Elsevier Inc.
Dekanski, A., Stevanovic, J., Stevanovic, R., Nikolic, B. Z., & Jovanovic, V. M. (2001).
Glassy carbon electrodes I . Characterization and electrochemical activation.
Carbon, 39, 1195–1205.
Deutch, A. Y. (1993). Prefrontal cortical dopamine systems and the elaboration of
functional corticostriatal circuits: implications for schizophrenia and Parkinson’s
disease A. Journal of Neural Transmission, 91, 197–221.
Dong, X., Qi, X., Liu, N., Yang, Y., & Piao, Y. (2017). Direct electrochemical detection
of bisphenol a using a highly conductive graphite nanoparticle film electrode.
Sensors, 17(4), 836-846.
Electrochemical impedance spectroscopy (2020). Retrived from
https://www.elproscan.com/secm/electrochemical-impedance-spectroscopy/
El Bouabi, Y., Farahi, A., Labjar, N., El Hajjaji, S., Bakasse, M., & El Mhammedi, M.
A. (2016). Square wave voltammetric determination of paracetamol at chitosan
modified carbon paste electrode: Application in natural water samples,
commercial tablets and human urines. Materials Science and Engineering C, 58,
70–77.
El Harrad, L., Bourais, I., Mohammadi, H., & Amine, A. (2018). Recent advances in
electrochemical biosensors pharmaceutical applications. Sensors, 18(1), 164–188.
Elgrishi, N., Rountree, K. J., Mccarthy, B. D., Rountree, E. S., Eisenhart, T. T., &
Dempsey, J. L. (2018). A Practical beginner’s guide to cyclic voltammetry.
Journal of Chemical Education, 95(2), 197–206.
Ensafi, A. A., Arashpour, B., Rezaei, B., & Allafchian, A. R. (2014). Voltammetric
behavior of dopamine at a glassy carbon electrode modified with NiFe2O4
magnetic nanoparticles decorated with multiwall carbon nanotubes. Materials
Science and Engineering C, 39(1), 78–85.
Ensafi, A. A., Karimi-maleh, H., Mallakpour, S., & Hatami, M. (2011). Simultaneous
determination of N-acetylcysteine and acetaminophen by modified multiwall
carbon nanotubes paste electrode. Sensors & Actuators B: Chemical, 155(2), 464–
472.
Erden, P. E., Kaçar, C., Öztürk, F., & Kiliç, E. (2015). Amperometric uric acid
biosensor based on poly(vinylferrocene)-gelatin-carboxylated multiwalled carbon
nanotube modified glassy carbon electrode. Talanta, 134, 488–495.
Eshaq, G., & Elmetwally, A. E. (2016). (Mg–Zn)–Al layered double hydroxide as a
regenerable catalyst for the catalytic glycolysis of polyethylene terephthalate.
Journal of Molecular Liquids, 214, 1–6.
Evans, D. G., & Slade, R. C. T. (2006). Structural aspects of layered double hydroxides.
In Duan. X. & Evans. D.G. (Eds.), Layered Double Hydroxides. Structure and
Bonding (Vol. 119, pp. 1–87). Germany: Springer, Berlin, Heidelberg.
Fan, G., Li, F., Evans, D. G., & Duan, X. (2014). Catalytic applications of layered
double hydroxides: Recent advances and perspectives. Chemical Society Review,
43, 7040–7066.
Fan, H., Li, Y., Wu, D., Ma, H., Mao, K., Fan, D., et al. (2012). Electrochemical
bisphenol A sensor based on N-doped graphene sheets. Analytica Chimica Acta,
711, 24–28.
Faridbod, F., Gupta, V. K., & Zamani, H. A. (2011). Electrochemical sensors and
biosensors. International Journal of Electrochemistry, 2011, 1-2.
Feitknecht, W. (1942). The knowledge of the double hydroxides and basic double salts.
Helvetica Chimica Acta, 25, 131–137.
Feng, J., Tao, Y., Shen, X., Jin, H., Zhou, T., Zhou, Y., et al. (2018). Highly sensitive
and selective fluorescent sensor for tetrabromobisphenol-A in electronic waste
samples using molecularly imprinted polymer coated quantum dots.
Microchemical Journal, 144, 93-101.
Ferraro, P. M., & Curhan, G. C. (2017). Serum uric acid and risk of kidney stones.
American Journal of Kidney Diseases, 70(2), 158–159.
Ferrer, E., Santoni, E., Vittori, S., Font, G., Mañes, J., & Sagratini, G. (2011).
Simultaneous determination of bisphenol A, octylphenol, and nonylphenol by
pressurised liquid extraction and liquid chromatography-tandem mass
spectrometry in powdered milk and infant formulas. Food Chemistry, 126(1),
360–367.
Flint, S., Markle, T., Thompson, S., & Wallace, E. (2012). Bisphenol A exposure,
effects, and policy : A wildlife perspective. Journal of Environmental
Management, 104, 19–34.
Frye, C. A., Bo, E., Calamandrei, G., Calze, L., Dessi-Fulgheri, F., Fernandez, M., et
al. (2011). Endocrine disrupters : A review of some sources, effects, and
mechanisms of actions on behaviour and neuroendocrine systems
neuroendocrinology system. Journal of Neuroendocrinol, 24(1), 144–159.
Ganesh, V., Pal, S. K., Kumar, S., & Lakshminarayanan, V. (2006). Self-assembled
monolayers (SAMs) of alkoxycyanobiphenyl thiols on gold—A study of electron
transfer reaction using cyclic voltammetry and electrochemical impedance
spectroscopy. Journal of Colloid and Interface Sciene, 296, 195–203.
Gao, Y., Cao, Y., Yang, D., Luo, X., Tang, Y., & Li, H. (2012). Sensitivity and
selectivity determination of bisphenol A using SWCNT-CD conjugate modified
glassy carbon electrode. Journal of Hazardous Materials, 199–200, 111–118.
Gautam, V., Singh, K. P., & Yadav, V. L. (2018). Preparation and characterization of
green-nano-composite material based on polyaniline, multiwalled carbon nano
tubes and carboxymethyl cellulose: For electrochemical sensor applications.
Carbohydrate Polymers, 189, 218-228
Germer, T. A., Zwinkels, J. C., & Tsai, B. K. (2014). Introduction to
Spectrophotometry. In T. A. Germer, J. C. Zwinkels, & P. S. Tsai (Eds.),
Spectrophotometry (Vol. 46, pp. 1–9). Academic Press.
Ghalkhani, M., & Ghorbani-Bidkorbeh, F. (2019). Development of carbon
nanostructured based electrochemical sensors for pharmaceutical analysis. Iranian
Journal of Pharmaceutical Research, 18(2), 658–669.
Ghanam, A., Lahcen, A. A., & Amine, A. (2017). Electroanalytical determination of
bisphenol A: Investigation of electrode surface fouling using various carbon
materials. Journal of Electroanalytical Chemistry, 789, 58–66.
Ghazali, S. A. I. S. M., Hussein, M. Z., & Sarijo, S. H. (2013). 3,4-
Dichlorophenoxyacetate interleaved into anionic clay for controlled release
formulation of a new environmentally friendly agrochemical. Nanoscale Research
Letters, 8, 362–369.
Ghiaci, M., Rezaei, B., & Arshadi, M. (2009). Characterization of modified carbon
paste electrode by using Salen Schiff base ligand immobilized on SiO2-Al2O3 as a
highly sensitive sensor for anodic stripping voltammetric determination of
copper(II). Sensors and Actuators, B: Chemical, 139(2), 494–500.
Gorkina, A. L., Tsapenko, A. P., Gilshteyn, E. P., Koltsova, T. S., Larionova, T. V,
Talyzin, A., et al. (2016). Transparent and Conductive Hybrid Graphene/Carbon
Nanotube Films. Carbon. Elsevier Ltd.
Grossmann, K., & Scheltrup, F. (1998). Studies on the mechanism of selectivity of the
auxin herbicide quinmerac. Pesticide Science, 52(2), 111–118.
Gulaboski, R., Mirceski, V., Komorsky-Lovric, S., & Lovric. M. (2004). Square-wave
voltammetry of cathodic stripping reactions. Diagnostic criteria , redox kinetic
measurements, and analytical applications. Electroanalysis, 16(10), 832–842.
Guo, X. M., Guo, B., Li, C., & Wang, Y. L. (2016). Amperometric highly sensitive uric
acid sensor based on manganese(III)porphyrin-graphene modified glassy carbon
electrode. Journal of Electroanalytical Chemistry, 783, 8–14.
Hao, Y., Xiao, F., Xiao-Xia, C., Jin-Li, Q., Xiao-Ling, G., Na, X., et al. (2017).
Electrochemical determination of bisphenol a on a glassy carbon electrode
modified with gold nanoparticles loaded on reduced graphene oxide-multi walled
carbon nanotubes composite. Chinese Journal of Analytical Chemistry, 45(5),
713–720.
Hashim, N., Hussein, M. Z., Yahaya, A. H., & Zainal, Z. (2007). Formation of zinc
aluminium layered double hydroxides-4(2,4-dichlorophenoxy)butyrate
nanocomposites by direct and indirect methods. The Malaysian Journal of
Analytical Sciences, 11(1), 1–7.
Hashim, N., Sharif, S. N. M., md isa, I., Mamat, M., Mohd Ali, N., Suriani, A. B., et al.
(2019). Intercalation and characterisation of novel broad-leaved herbicide
nanocomposite from zinc/aluminium layered double hydroxide and quinmerac.
Research Journal of Chemistry And Environment, 23, 36–45.
He, J., Wei, M., Li, B., Kang, Y., Evans, D. G., & Duan, X. (2006). Preparation of
layered double hydroxides. In X. Duan & D. G. Evans (Eds.), Layered Double
Hydroxides. Structure and Bonding (pp. 89–119). New York: Springer, Berlin,
Heidelberg.
Hernández, M., Fernández, L., Borrás, C., Mostany, J., & Carrero, H. (2007).
Characterization of surfactant/hydrotalcite-like clay/glassy carbon modified
electrodes: Oxidation of phenol. Analytica Chimica Acta, 597(2), 245–256.
Hochstetter, C. (1842). Investigation of the composition of some minerals. Journal for
Practical Chemistry, 27, 375–378.
Honeychurch, K. C. (2012). Printed thick-film biosensors. In Printed Films (pp. 366–
409). Woodhead Publishing.
Howes, O., Mccutcheon, R., & Stone, J. (2015). Glutamate and dopamine in
schizophrenia : An update for the 21 st century. Journal of Psychopharmacology,
29(2), 97-115.
Huang, H., Mao, L., Li, Z., Liu, Y., Fan, S., Jin, Y., et al. (2019). Multifunctional
Polypyrrole-silver coated layered double hydroxides embedded into a
biodegradable polymer matrix for enhanced antibacterial and gas barrier
properties. Journal of Bioresources and Bioproducts, 4(4), 231–241.
Huang, L., Jiao, S., & Li, M. (2014). Determination of uric acid in human urine by
eliminating ascorbic acid interference on copper(II)-polydopamine immobilized
electrode surface. Electrochimica Acta, 121, 233–239.
Huang, Y., Cheng, C., Tian, X., Zheng, B., Li, Y., Yuan, H., et al. (2013). Low-potential
amperometric detection of dopamine based on MnO2 nanowires/chitosan modified
gold electrode. Electrochimica Acta, 89, 832–839.
Huang, Y., Li, X., & Zheng, S. (2016). A novel and label-free immunosensor for
bisphenol A using rutin as the redox probe. Talanta, 160, 241–246.
Huang, Y. Q., Wong, C. K. C., Zheng, J. S., Bouwman, H., Barra, R., Wahlström, B.,
et al. (2012). Bisphenol A (BPA) in China: A review of sources, environmental
levels, and potential human health impacts. Environment International, 42, 91–99.
Hudari, F. F., Duarte, E. H., Pereira, A. C., Dall‘Antonia, L. H., Kubota, L. T., & Tarley,
C. R. T. (2013). Voltammetric method optimized by multi-response assays for the
simultaneous measurements of uric acid and acetaminophen in urine in the
presence of surfactant using MWCNT paste electrode. Journal of
Electroanalytical Chemistry, 696, 52–58.
Hussein, M. Z., Hashim, N., Yahaya, A. H., & Zainal, Z. (2010). Synthesis of an
herbicides–inorganic nanohybrid compound by ion exchange-intercalation of 3(2-
chlorophenoxy) propionate into layered double hydroxide. Journal of
Experimental Nanoscience, 5(6), 548–558.
Hussein, M. Z., Rahman, N. S. S. A., Sarijo, S. H., & Zainal, Z. (2012). Synthesis of a
monophasic nanohybrid for a controlled release formulation of two active agents
simultaneously. Applied Clay Science, 58, 60–66.
Hyllested, M., Jones, S., Pedersen, J. L., & Kehlet, H. (2002). Comparative effect of
paracetamol, NSAIDs or their combination in postoperative pain management: A
qualitative review. British Journal of Anaesthesia, 88(2), 199–214.
Inzelt, G. (2014). Chronoamperometry, chronocoulometry, and chronopotentiometry.
In G. Kreysa, K. Ota, & R. F. Savinell (Eds.), Encyclopedia of Applied
Electrochemistry (pp. 207–214). New York, NY: Springer New York.
Irdemez, S., & Tosunoglu, N. D. V. (2011). The effects of supporting electrolyte type
and concentration on the phosphate removal from wastewater by
electrocoagulation with aluminum plate electrodes. Igdir University Journal of the
Institute of Science and Technology, 1(2), 35–40.
Isa, I., Fasyir, M. R., Hashim, N., Ghani, S. A., Bakar, S. A., Mohamed, A., & Kamari,
A. (2015). A highly sensitive mercury (II) sensor using Zn/Al layered double
hydroxide-3(4-hydroxyphenyl) propionate modified multi-walled carbon
nanotube paste electrode. International Journal of Electrochemical Science, 10,
6227–6240.
Isa, I. M., Saidin, M. I., Ahmad, M., Hashim, N., Bakar, S. A., Ali, N. M., & Si, S. M.
(2017). Chloroplatinum(II) complex-modified MWCNTs paste electrode for
electrochemical determination of mercury in skin lightening cosmetics.
Electrochimica Acta, 253, 463-471.
Isa, I. M., Saruddin, S., Hashim, N., Ahmad, M., & Ghani, S. A. (2016). Determination
of hydrazine in various water samples by square wave voltammetry with zinclayered
hydroxide-3(4-methoxyphenyl) propionate nanocomposite modified
glassy carbon electrode. International Journal of Electrochemical Science, 11(6),
4619–4631.
Isa, I. M., Sharif, S. N. M., Hashim, N., & Ghani, S. A. (2015). Amperometric
determination of nanomolar mercury(II) by layered double nanocomposite of
zinc/aluminium hydroxide-3(4-methoxyphenyl)propionate modified singlewalled
carbon nanotube paste electrode. Ionics, 21(10), 2949–2958.
Jemelkova, Z., Barek, J., & Zima, J. (2010). Determination of epinephrine at different
types of carbon paste electrodes. Analytical Letters, 43(7), 1367–1376.
Kalambate, P. K., & Srivastava, A. K. (2016). Simultaneous voltammetric
determination of paracetamol, cetirizine and phenylephrine using a multiwalled
carbon nanotube-platinum nanoparticles nanocomposite modified carbon paste
electrode. Sensors and Actuators, B: Chemical, 233, 237–248.
Kalcher, K. (1990). Chemically Modified carbon paste electrodes in voltammetric
analysis. Electroanalysis, 2(6), 419–433.
Kalcher, K., Kauffmann, J.-M., Wang, J., Svancara, I., Vytras, K., Neuhold, C., &
Yang, Z. (1995). Sensors based on carbon paste in electrochemical analysis: A
review with particular emphasis on the period 1990-1993. Electroanalysis, 7(1),
5–22.
Kalimuthu, P., & John, S. A. (2011). Selective determination of 3,4-
dihydroxyphenylacetic acid in the presence of ascorbic and uric acids using
polymer film modified electrode. Journal of Chemical Sciences, 123(3), 349–355.
Kameda, T., Takeuchi, H., & Yoshioka, T. (2009). Hybrid inorganic/organic
composites of Mg–Al layered double hydroxides intercalated with citrate, malate,
and tartrate prepared by co-precipitation. Materials Research Bulletin, 44, 840–
845.
Kang, J.-H., Kito, K., & Kondo, F. (2003). Factors influencing the migration of
bisphenol A from cans. Journal of Food Protection, 66(8), 1444–1447.
Kannan, P. K., Hu, C., Morgan, H., Moshkalev, S., A. & Rout, C. S. (2016).
Electrochemical sensing of bisphenol using a multilayer graphene nanobelt
modified photolithography patterned platinum electrode. Nanotechnology, 27,
37504.
Kannan, A., & Sevvel, R. (2017). A highly selective and simultaneous determination
of paracetamol and dopamine using poly-4-amino-6-hydroxy-2-
mercaptopyrimidine (Poly-AHMP) film modified glassy carbon electrode.
Journal of Electroanalytical Chemistry, 791, 8–16.
Karimi-maleh, H., Karimi, F., Alizadeh, M., & Sanati, A. L. (2020). Electrochemical
sensors, a bright future in the fabrication of portable kits in analytical systems. The
Chemical Record, 20(7), 1–12.
Kaya, S. I., Karabulut, T. C., Kurbanoglu, S., & Ozkan, S. A. (2020). Chemically
modified electrodes in electrochemical drug analysis. Current Pharmaceutical
Analysis, 16(6), 641-660.
Kesebir, S., Yaylaci, E. T., Süner, Ö., & Gültekin, B. K. (2014). Uric acid levels may
be a biological marker for the differentiation of unipolar and bipolar disorder: The
role of affective temperament. Journal of Affective Disorders, 165, 131–134.
Keyvanfard, M., Shakeri, R., Karimi-Maleh, H., & Alizad, K. (2013). Highly selective
and sensitive voltammetric sensor based on modified multiwall carbon nanotube
paste electrode for simultaneous determination of ascorbic acid, acetaminophen
and tryptophan. Materials Science and Engineering C, 33(2), 811–816.
Khan, M. I., Haque, A. J., & Kim, K. (2013). Electrochemical determination of uric
acid in the presence of ascorbic acid on electrochemically reduced graphene oxide
modified electrode. Journal of Electroanalytical Chemistry, 700, 54-59.
Khaskheli, A. R., Fischer, J., Barek, J., Vysko?cil, V., Sirajuddin, & Bhanger, M. I.
(2013). Differential pulse voltammetric determination of paracetamol in tablet and
urine samples at a micro-crystalline natural graphite–polystyrene composite film
modified electrode. Electrochimica Acta, 101, 238–242.
Kim, D., Lee, S., & Piao, Y. (2017a). Electrochemical determination of dopamine and
acetaminophen using activated graphene-Nafion modified glassy carbon
electrode. Journal of Electroanalytical Chemistry, 794, 221–228.
Kim, M., Eun, Y., Xiong, J., Kim, K., Jang, M., Jeon, B., et al. (2021). Electrochemical
detection and simultaneous removal of endocrine disruptor , bisphenol A using a
carbon felt electrode. Journal of Electroanalytical Chemistry, 880, 114907.
Kong, R. (2005). LC/MS application in high-throughput ADME Screen. In S. Ahuja &
M. W. Dong (Eds.), Handbook of Pharmaceutical Analysis by HPLC (Vol. 6, pp.
413–446). Academic Press.
Kounaves, S. P. (1998). Voltammetric techniques. In Handbook of Instrumental
Techniques for Analytical Chemistry (pp. 709–726). Taylor & Francis.
Krulic, D., & Fatouros, N. (2011). Peak heights and peak widths at half-height in square
wave voltammetry without and with ohmic potential drop for reversible and
irreversible systems. Journal of Electroanalytical Chemistry, 652, 26-31.
Kumar, Y., Pramanik, P., & Das, D. K. (2019). Electrochemical detection of
paracetamol and dopamine molecules using nano-particles of cobalt ferrite and
manganese ferrite modified with graphite. Heliyon, 5(7), e02031.
Kuramoto, K., Intasa-Ard, S. (Grace), Bureekaew, S., & Ogawa, M. (2017).
Mechanochemical synthesis of finite particle of layered double hydroxide-acetate
intercalation compound: Swelling, thin film and ion exchange. Journal of Solid
State Chemistry, 253, 147–153.
Kuthati, Y., Kankala, R. K., & Lee, C. (2015). Layered double hydroxide nanoparticles
for biomedical applications: Current status and recent prospects. Applied Clay
Science, 112–113, 100–116.
Kutzing, M. K., & Firestein, B. L. (2008). Altered uric acid levels and disease states.
Perspective in Pharmacology, 324(1), 1–7.
Lakshmi, D., Whitcombe, M. J., Davis, F., Sharma, S., & Prasad, B. (2011).
Electrochemical detection of uric acid in mixed and clinical samples: A Review.
Electroanalysis, 23(2), 305–320.
Lasia, A. (1999). Electrochemical impedance spectroscopy and its applications. In
Modern Aspects of Electrochemistry (pp. 143–248). Boston: Springer.
Laviron, E., & Roullier, L. (1983). Electrochemical reactions with protonations at
equilibrium. Journal of Electroanalytical Chemistry and Interfacial
Electrochemistry, 157(1), 7–18.
Lee, J. (2014). Electrochemical Sensing of Oxygen Gas in Ionic Liquids on Screen
Printed Electrodes. Curtin University.
Lehotay, S. J., & Schenck, F. J. (2000). Multiresidue methods: Extraction. In
Encyclopedia of Separation Science (pp. 3409–3415). Oxford: Academic Press.
Li, F., Wang, Y., Yang, Q., Evans, D. G., Forano, C., & Duan, X. (2005). Study on
adsorption of glyphosate (N-phosphonomethyl glycine) pesticide on MgAllayered
double hydroxides in aqueous solution. Journal of Hazardous Materials,
125, 89–95.
Li, L., Qi, G., Fukushima, M., Wang, B., Xu, H., & Wang, Y. (2017). Insight into the
preparation of Fe3O4 nanoparticle pillared layered double hydroxides composite
via thermal decomposition and reconstruction. Applied Clay Science, 140, 88–95.
Li, M., Zhu, J. E., Zhang, L., Chen, X., Zhang, H., Zhang, F., et al. (2011). Facile
synthesis of NiAl-layered double hydroxide/graphene hybrid with enhanced
electrochemical properties for detection of dopamine. Nanoscale, 3(10), 4240–
4246.
Li, Q., Qiu, Y., Han, W., Zheng, Y., Wang, X., Xiao, D., et al. (2018). Determination
of uric acid in biological samples by high performance liquid chromatographyelectrospray
ionization-tandem mass spectrometry and study on pathogenesis of
pulmonary arterial hypertension in pulmonary artery endothelium cells. Royal
Society of Chemistry, 8, 25808–25814.
Li, S., Zhang, J., Li, J., Yang, H., Meng, J., & Zhang, B. (2017). A 3D sandwich
structured hybrid of gold nanoparticles decorated MnO2/graphene-carbon
nanotubes as high performance H2O2 sensors. Sensors & Actuators B: Chemical,
260, 1-11.
Li, X., Li, S., Bai, J., Peng, Y., Ning, B., Shi, H., et al. (2019). Determination of
bisphenol A by high-performance liquid chromatography based on graphene
magnetic dispersion solid phase extraction. Journal of Chromatographic Science,
58(3), 280-286.
Li, Y., Gao, Y., Cao, Y., & Li, H. (2012). Electrochemical sensor for bisphenol A
determination based on MWCNT/melamine complex modified GCE. Sensors &
Actuators B: Chemical, 171–172, 726–733.
Li, Y., Liu, J., Liu, M., Yu, F., Zhang, L., Tang, H., et al. (2016). Fabrication of ultrasensitive
and selective dopamine electrochemical sensor based on molecularly
imprinted polymer modified graphene@carbon nanotube foam. Electrochemistry
Communications, 64, 42–45.
Li, Y., Xu, W., Zhao, X., Huang, Y., Kang, J., Qi, Q., & Zhong, C. (2018).
Electrochemical sensors based on molecularly imprinted polymer on
Fe3O4/graphene modified by gold nanoparticles for highly selective and sensitive
detection of trace ractopamine in water. Analyst, 143(21), 5094-5102.
Li, Y., Zhai, X., Liu, X., Wang, L., Liu, H., & Wang, H. (2016). Electrochemical
determination of bisphenol A at ordered mesoporous carbon modified nanocarbon
ionic liquid paste electrode. Talanta, 148, 362–369.
Lian, H., Sun, Z., Sun, X. & Liu, B. (2012). Graphene doped molecularly imprinted
electrochemical sensor for uric acid. Analytical Letters, 45, 2717-2727.
Lin, C., Li, P., Yang, M., Ye, J., & Huang, X. (2019). Metal replacement causing
interference in stripping analysis of multiple heavy metal analytes: Kinetic study
on Cd(II) and Cu(II) electroanalysis via experiment and simulation. Analytical
Chemistry, 91(15), 9978-9985.
Lisdat, F., & Schäfer, D. (2008). The use of electrochemical impedance spectroscopy
for biosensing. Analytical and Bioanalytical Chemistry, 391(5), 1555–1567.
Liu, Q., Kang, X., Xing, L., Ye, Z., & Yang, Y. (2020). A facile synthesis of
nanostructured CoFe2O4 for the electrochemical sensing of bisphenol A. Royal
Society of Chemistry Advances, 10(11), 6156–6162.
Locke, C. J., Fox, S. A., Caldwell, G. A., & Caldwell, K. A. (2008). Acetaminophen
attenuates dopamine neuron degeneration in animal models of Parkinson’s
disease. Neuroscience Letters, 439, 129–133.
Lubert, K., & Kalcher, K. (2010). History of electroanalytical methods.
Electroanalysis, 22, 1937–1946.
Ma, B., Guo, H., Wang, M., Li, L., Jia, X., Chen, H., et la. (2019). Electrocatalysis of
Cu−MOF/graphene composite and its sensing application for electrochemical
simultaneous determination of dopamine and paracetamol. Electroanalysis, 31(6),
1002–1008.
Mabbott, G. A. (1983). An introduction to cyclic voltammetry. Journal of Chemical
Education, 60(9), 697–702.
Macdonald, A. A., Seergobin, K. N., Owen, A. M., Tamjeedi, R., Monchi, O., Ganjavi,
H., et al. (2013). Differential effects of Parkinson’s disease and dopamine
replacement on memory encoding and retrieval. PLoS One, 8(9), e74044.
Black, M. (1984). Acetaminophen hepatotoxicity. Annual Reviews of Medicine, 35(5),
577–593.
Mashhadizadeh, M. H., & Akbarian, M. (2009). Voltammetric determination of some
anti-malarial drugs using a carbon paste electrode modified with Cu(OH)2 nanowire.
Talanta, 78, 1440–1445.
Mazloum-Ardakani, M., Rajabzadeh, N., Deghani-Firouzabadi, A., Sheikh-Mohseni,
M. A., Benvidi, A., Naeimi, H., et al. (2012). Analytical methods carbon
nanoparticles and a new derivative of hydroquinone for modification of a carbon
paste electrode for simultaneous determination of epinephrine and acetaminophen.
Analytical Methods, 4, 2127–2133.
McDonald, J. G., Ivanova, P. T., & Brown, H. A. (2016). Approaches to lipid analysis.
In Biochemistry of Lipids, Lipoproteins and Membranes: Sixth edition (pp. 41–
72). Elsevier Inc.
Mehri-Talarposhti, F., Saraei, A. G. H., Karimi-Maleh, H., Golestan, L., & Shahidi, S.
A. (2020). Determination of bisphenol in food samples using an electrochemical
method based on modification of a carbon paste electrode with CdO
nanoparticle/ionic liquid. International Journal of Electrochemical Science, 15(3),
1904–1914.
Mendoza-Huizar, L. H. (2014). Chemical reactivity of quinmerac herbicide through the
Fukui function. Acta Chimica Slovenica, 61(4), 694–702.
Messaoud, N. Ben, Ghica, M. E., Ali, M. Ben, & Brett, C. M. A. (2017).
Electrochemical sensor based on multiwalled carbon nanotube and gold
nanoparticle modified electrode for the sensitive detection of bisphenol A. Sensors
& Actuators B: Chemical, 253, 513–522.
Mirceski, V., Gulaboski, R., Lovric, M., Bogeski, I., & Kappl, R. (2013). Square-wave
voltammetry: A review on the recent progress. Electroanalysis, 25(11), 2411–
2422.
Mirzahosseini, A., Palla, T., Orgovan, G., Toth, G., Noszal, B. (2018). Dopamine:
Acid-base properties and membrane penetration capacity. Journal of
Pharmaceutical and Biomedical Analysis, 158, 346–350.
Mishra, G., Dash, B., & Pandey, S. (2018). Layered double hydroxides: A brief review
from fundamentals to application as evolving biomaterials. Applied Clay Science,
153, 172–186.
Molaakbari, E., Mostafavi, A., & Beitollahi, H. (2014). Simultaneous electrochemical
determination of dopamine, melatonin, methionine and caffeine. Sensors &
Actuators B: Chemical, 208, 195–203.
Morel-Desrosiers, N., Pisson, J., Israeli, Y., Taviot-Gueho, C., Besse, J.-P., & Morel,
J.-P. (2003). Intercalation of dicarboxylate anions into a Zn–Al–Cl layered double
hydroxide: Microcalorimetric determination of the enthalpies of anion exchange.
Journal of Materials Chemistry, 13, 2582–2585.
Morris, R. (2015). Spectrophotometry. Current Protocols Essential Laboratory
Techniques, 11(1), 1–30.
Moscatello, J. P., Prasad, A., Chintala, R., & Yap, Y. K. (2012). A simple scheme of
molecular electronic devices with multiwalled carbon nanotubes as the top
electrodes. Carbon, 50(10), 3530–3534.
Musshoff, F., Schmidt, P., Dettmeyer, R., Priemer, F., Jachau, K., & Madea, B. (2000).
Determination of dopamine and dopamine-derived (R)-/(S)-salsolinol and
norsalsolinol in various human brain areas using solid-phase extraction and gas
chromatography/mass spectrometry. Forensic Science International, 113, 359–
366.
Naegeli, R., Redepenning, J., & Anson, F. C. (1986). Influence of supporting electrolyte
concentration and composition on formal potentials and entropies of redox couples
incorporated in nafion coatings on electrodes. Journal of Physical Chemistry,
90(23), 6227–6232.
Najafi, M., Khalilzadeh, M. A., & Karimi-maleh, H. (2014). A new strategy for
determination of bisphenol A in the presence of Sudan I using a ZnO/CNTs/ionic
liquid paste electrode in food samples. Food Chemistry, 158, 125–131.
Nakamura, K., Itoh, K., Dai, H., Han, L., Wang, X., Kato, S., et al. (2012). Prenatal and
lactational exposure to low-doses of bisphenol A alters adult mice behavior. Brain
and Development, 34(1), 57–63.
Nakayama, H., Wada, N., & Tsuhako, M. (2004). Intercalation of amino acids and
peptides into Mg–Al layered double hydroxide by reconstruction method.
International Journal of Pharmaceutics, 269, 469–478.
Nambudumada, P. S., Manjunatha, J. G., & Chenthattil, R. (2019). Electrocatalytic
analysis of dopamine, uric acid and ascorbic acid at poly(adenine) modified carbon
nanotube paste electrode: A Cyclic voltammetric study. Analytical &
Bioanalytical Electrochemistry, 11(6), 742–756.
Narayana, P. V., Reddy, T. M., Gopal, P., & Naidu, G. R. (2014). Electrochemical
sensing of paracetamol and its simultaneous resolution in the presence of
dopamine and folic acid at a multi-walled carbon nanotubes/poly(glycine)
composite modified electrode. Analytical Methods, 6(23), 9459–9468.
Newman, S. P., & Jones, W. (1998). Synthesis, characterization and applications of
layered double hydroxides containing organic guests. New Journal of Chemistry,
22, 105–115.
Ni, F., Wang, Y., Zhang, D., Gao, F., & Li, M. (2010). Electrochemical oxidation of
epinephrine and uric acid at a layered double hydroxide film modified glassy
carbon electrode and its application. Electroanalysis, 22(10), 1130–1135.
Nieszporek, J., Gugala-Fekner, D., & Nieszporek, K. (2019). The effect of supporting
electrolyte concentration on zinc electrodeposition kinetics from methimazole
solutions. Electroanalysis, 31(6), 1141–1149.
Nikahd, B., & Khalilzadeh, M. A. (2016). Liquid phase determination of bisphenol A
in food samples using novel nanostructure ionic liquid modified sensor. Journal
of Molecular Liquids, 215, 253–257.
Niu, X., Yang, W., Wang, G., Ren, J., Guo, H., & Gao, J. (2013). A novel
electrochemical sensor of bisphenol A based on stacked graphene nanofibers/gold
nanoparticles composite modified glassy carbon electrode. Electrochimica Acta,
98, 167–175.
Nkunu, Z. N., Kamau, G. N., Kithure, J. G., & Muya, C. N. (2017). Electrochemical
studies of potassium ferricyanide in acetonitrile-water media (1:1) using cyclic
voltammetry method. International Journal of Scientific Research and Innovative
Technology, 4(5), 2313–3759.
Noroozifar, M., Khorasani-motlagh, M., Jahromi, F. Z., & Rostami, S. (2013). Sensitive
and selective determination of uric acid in real samples by modified glassy carbon
electrode with holmium fluoride nanoparticles/multi-walled carbon nanotube as a
new biosensor. Sensors & Actuators: B. Chemical, 188, 65–72.
Nuki, G., & Simkin, P. A. (2006). A concise history of gout and hyperuricemia and
their treatment. Arthritis Research & Therapy, 8, 1–5.
Olaleye, M. T., & Rocha, B. T. J. (2008). Acetaminophen-induced liver damage in
mice: Effects of some medicinal plants on the oxidative defense system.
Experimental and Toxicologic Pathology, 59, 319–327.
Osteryoung, J. G., & Osteryoung, R. A. (1985). Square wave voltammetry. Analytical
Chemistry, 57(1), 101–102.
Ostoji, J., Herenda, S., Besic, Z., Milos, M., & Galic, B. (2017). Advantages of an
electrochemical method compared to the spectrophotometric kinetic study of
peroxidase inhibition by boroxine derivative. Molecules, 22, 1120–1128.
Ötles, S. (2016). Handbook of food analysis instruments. (S. Otles, Ed.). Boca Raton:
CRC Press.
Ouassif, H., Moujahid, E. M., Lahkale, R., Sadik, R., Bouragba, F. Z., Sabbar, E.
mouloudi, & Diouri, M. (2020). Zinc-aluminum layered double hydroxide: High
efficient removal by adsorption of tartrazine dye from aqueous solution. Surfaces
and Interfaces, 18, 100401.
Palza, H., Delgado, K., & Govan, J. (2019). Novel magnetic CoFe2O4/layered double
hydroxide nanocomposites for recoverable anionic adsorbents for water treatment.
Applied Clay Science, 183(4), 105350.
Panahi, Y., Motaharian, A., Reza, M., Hosseini, M., & Mehrpour, O. (2018). High
sensitive and selective nano-molecularly imprinted polymer based
electrochemical sensor for midazolam drug detection in pharmaceutical
formulation and human urine samples. Sensors & Actuators B: Chemical, 273(2),
1579–1586.
Háková, M., Havlíková, L. C., Chvojka, J., Solich, P., & Šatínský, D. (2018). An online
coupling of nanofibrous extraction with column-switching high performance
liquid chromatography-A case study on the determination of bisphenol A in
environmental water samples. Talanta, 178(2), 141-146.
Podlipna, D., & Cichna-Markl, M. (2007). Determination of bisphenol A in canned fish
by sol-gel immunoaffinity chromatography, HPLC and fluorescence detection.
European Food Research and Technology, 224(5), 629–634.
Prabakar, S. J. R., & Narayanan, S. S. (2007). Amperometric determination of
paracetomol by a surface modified cobalt hexacyanoferrate graphite wax
composite electrode. Talanta, 72(5), 1818–1827.
Price, H. (2019). Air analysis: Field portable instruments for the measurement of
airborne hazards. In Encyclopedia of Analytical Science (3rd ed., pp. 40–43).
Stirling, United Kingdom: Elsevier Inc.
Qiu, D., Hou, W., Xu, J., Liu, J., & Liu, S. (2009). Synthesis and characterization of
imidacloprid/hydrotalcite-like compound nanohybrids. Chinese Journal of
Chemistry, 27, 1879–1885.
Qu, W., & Meyer, J.-U. (1997). Thick-film humidity sensor based on porous MnWO4
material. Measurement Science and Technology, 8(6), 593–600.
Rais, N. S. M., Isa, I. M., Hashim, N., Saidin, M. I., Yazid, S. N. A. M., Ahmad, M. S.,
et al. (2019). Simultaneously determination of bisphenol A and uric acid by
zinc/aluminum-layered double hydroxide-2-(2,4-dichlorophenoxy) propionate
paste electrode. International Journal of Electrochemical Science, 14(8), 7911–
7924.
Raj, C. R., & Ohsaka, T. (2003). Voltammetric detection of uric acid in the presence of
ascorbic acid at a gold electrode modified with a self-assembled monolayer of
heteroaromatic thiol. Journal of Electroanalytical Chemistry, 540, 69–77.
Rajakumaran, R., Ramki, S., Chen, S. M., Chen, T. W., Veerasankar, S., Tseng, T. W.,
& Huang, C. C. (2019). Rose-petal-like morphology of yttrium molybdate
nanosheets (YMoO4) anchored on functionalized carbon nanofibers: An efficient
electrocatalyst for the electrochemical sensing of bisphenol-A. International
Journal of Electrochemical Science, 14(7), 6571–6585.
Ramesh, P., & Sampath, S. (2004). Selective determination of uric acid in presence of
ascorbic acid and dopamine at neutral pH using exfoliated graphite electrodes.
Electroanalysis, 16(10), 866–869.
Raoof, J. B., Baghayeri, M., & Ojani, R. (2012). A high sensitive voltammetric sensor
for qualitative and quantitative determination of phenobarbital as an antiepileptic
drug in presence of acetaminophen. Colloids and Surfaces B: Biointerfaces, 95,
121–128.
Rezaei, B., & Irannejad, N. (2019). Electrochemical detection techniques in biosensor
applications. In E. Ensafi (Ed.), Electrochemical Biosensors (pp. 11–43). Elsevier
Inc.
Rives, V. (2001). Layered double hydroxides: Present and Future. New York: Nova
Publishers.
Rives, V., Arco, M. del, & Martín, C. (2014). Intercalation of drugs in layered double
hydroxides and their controlled release: A review. Applied Clay Science, 88–89,
239–269.
Rochester, J. R. (2013). Bisphenol A and human health: A review of the literature.
Reproductive Toxicology, 42, 132–155.
Rosu, D., Mustata, F., Tudorachi, N., Musteata, V. E., Rosu, L., & Varganici, C. D.
(2015). Novel bio-based flexible epoxy resin from diglycidyl ether of bisphenol A
cured with castor oil maleate. Royal Society of Chemistry Advances, 5(57), 45679–
45687.
Saal, F. S. vom, & Hughes, C. (2005). Commentary an extensive new literature
concerning low-dose effects of bisphenol A shows the need for a new risk
assessment. Environmental Health Perspectives, 113(8), 926–933.
Sabatani, E., & Rubinstein, I. (1987). Organized self-assembling monolayers on
electrodes. 2. Monolayer-based ultramicroelectrodes for the study of very
electrode kinetics. Journal of Electroanalytical Chemistry, 91, 6663–6669.
Saifullah, B., Zowalaty, M. E. El, Arulselvan, P., Fakurazi, S., Webster, T. J., Geilich,
B. M., & Hussein, M. Z. (2014). Antimycobacterial, antimicrobial and
biocompatibility properties of para-aminosalicylic acid with zinc layered
hydroxide and Zn/Al layered double hydroxide nanocomposites. Drug Design,
Development and Therapy, 8, 1029–1036.
Sapari, S., Hidayah, N., Razak, A., Aishah, S., & Yook, L. (2020). A regenerable
screen-printed voltammetric Hg (II) ion sensor based on tris-thiourea organic
chelating ligand grafted graphene nanomaterial. Journal of Electroanalytical
Chemistry, 878, 114670.
Sappia, L., Felice, B., Sanchez, M. A., Marti, M., R, M., & Pividori, I. (2019).
Electrochemical sensor for alkaline phosphatase as biomarker for clinical and in
vitro applications. Sensors & Actuators B: Chemical, 281(10), 221–228.
Sarijo, S. H., Hussein, M. Z., Yahaya, A. H. J., & Zainal, Z. (2010). Effect of incoming
and outgoing exchangeable anions on the release kinetics of phenoxyherbicides
nanohybrids. Journal of Hazardous Materials, 182(1–3), 563–569.
Sathisha, T. V, Swamy, B. E. K., Schell, M., & Eswarappa, B. (2014). Synthesis and
characterization of carbon nanoparticles and their modified carbon paste electrode
for the determination of dopamine. Journal of Electroanalytical Chemistry, 720–
721, 1–8.
Scholz, F. (2010). Electroanalytical methods: Guide to experiments and applications
(2nd ed.). Berlin: Springer-Verlag.
Segner, H., Navas, J. M., Schäfers, C., & Wenzel, A. (2003). Potencies of estrogenic
compounds in in vitro screening assays and in life cycle tests with zebrafish in
vivo. Ecotoxicology and Environmental Safety, 54(3), 315–322.
Shah, N., Arain, M. B., & Soylak, M. (2020). Historical background: milestones in the
field of development of analytical instrumentation. In New Generation Green
Solvents for Separation and Preconcentration of Organic and Inorganic Species
(pp. 45–73). Elsevier.
Shahmiri, M. R., Bahari, A., Karimi-maleh, H., Hosseinzadeh, R., & Mirnia, N. (2013).
Ethynylferrocene–NiO/MWCNT nanocomposite modified carbon paste electrode
as a novel voltammetric sensor for simultaneous determination of glutathione and
acetaminophen. Sensors & Actuators B: Chemical, 177, 70–77.
Shahrokhian, S., & Asadian, E. (2010). Simultaneous voltammetric determination of
ascorbic acid , acetaminophen and isoniazid using thionine immobilized multiwalled
carbon nanotube modified carbon paste electrode. Electrochimica Acta, 55,
666–672.
Sharif, S. N. M., Hashim, N., Isa, I. M., Ali, N. M., Bakar, S. A., Hussein, M. Z., et al.
(2018). Preparation and characterisation of novel paddy cultivation herbicide
nanocomposite from zinc/aluminium layered double hydroxide and quinclorac
anion. Materials Research Innovations, 23(5), 260–265.
Sharif, S. N. M., Hashim, N., Md Isa, I., Mamat, M., Mohd Ali, N., Abu Bakar, S., et
al. (2020). The intercalation behaviour and physico-chemical characterisation of
novel intercalated nanocomposite from zinc/aluminium layered double hydroxides
and broadleaf herbicide clopyralid. Chemistry & Chemical Technology, 14(1), 38–
46.
Sharma, A., Bhattarai, J. K., Nigudkar, S. S., Pistorio, S. G., Demchenko, A. V, & Stine,
K. J. (2016). Electrochemical impedance spectroscopy study of carbohydrateterminated
alkanethiol monolayers on nanoporous gold: Implications for pore
wetting. Journal of Electroanalytical Chemistry, 782, 174–181.
Shetti, N. P., Nayak, D. S., Malode, S. J., Kakarla, R. R., Shukla, S. S., & Aminabhavi,
T. M. (2018). Sensors based on ruthenium-doped TiO2 nanoparticles loaded into
multi-walled carbon nanotubes for the detection of flufenamic acid and mefenamic
acid. Analytica Chimica Acta, 1051, 58-72.
Shiffman, S., Battista, D. R., Kelly, J. P., Malone, M. K., Weinstein, R. B., & Kaufman,
D. W. (2018). Exceeding the maximum daily dose of acetaminophen with use of
different single-ingredient OTC formulations. Journal of the American
Pharmacists Association, 58(5), 499-504.
Skoog, D. A., Holler, F. J., & Crouch, S. R. (2007). Principles of Instrumental Analysis
(6th ed.). USA: Thomson Brooks/Cole.
Smyntyna, V., Golovanov, V., Kaeiulis, S., Mattogno, G., & Righini, G. (1995).
Influence of chemical composition on sensitivity and signal reproducibility of CdS
sensors of oxygen. Sensors & Actuator B: Chemical, 25, 628–630.
Sparkman, O. D., Penton, Z. E., & Kitson, F. G. (2011). The Fundamentals of GC/MS.
In Gas Chromatography and Mass Spectrometry (pp. 2–13). Amsterdam:
Academic Press.
Srinivas, J., Mascarenhas, R. J., D’Souza, O., Satpati, A. K., & Mekhalif, Z. (2017).
Electrocatalytic oxidation of bisphenol A at oxidized multi-walled carbon
nanotube modified carbon paste electrode. Analytical Chemistry Letters, 7(1), 52–
64.
Staples, C. A., Dom, P. B., Klecka, G. M., Sandra, T. O., & Harris, L. R. (1998). A
review of the environmental fate, effects and exposures of bisphenol A.Chemosphere, 36(10), 2149–2173.
Steventon, G. B., Heafield, M. T. E., Waring, R. H., Williams, A. C., Sturman, S., &
Green, M. (1990). Metabolism of low-dose paracetamol in patients with chronic
neurological disease. Xenobiotica, 20, 117–122.
Stradiotto, N. R., Yamanaka, H., & Zanoni, M. V. B. (2003). Electrochemical sensors:
A powerful tool in analytical chemistry. Journal of Brazilian Chemical Society,
14(2), 159–173.
Su, W. Y., & Cheng, S. H. (2010). Electrochemical oxidation and sensitive
determination of acetaminophen in pharmaceuticals at poly(3,4-ethylenedioxythiophene)-
modified screen-printed electrodes. Electroanalysis, 22(6), 707–
714.
Suni, I. I. (2008). Impedance methods for electrochemical sensors using nanomaterials.
Trends in Analytical Chemistry, 27(7), 604–611.
Suroviec, A. H. (2013). Introduction to electrochemistry. Journal of Laboratory
Chemical Education, 1(3), 45–48.
Švancara, I., Vytras, K., Barek, J., & Zima, J. (2001). Carbon paste electrodes in
modern electroanalysis electroanalysis. Critical Reviews in Analytical Chemistry,
31(4), 311–345.
Svancara, I., Vytras, K., Kalcher, K., Walcarius, A., & Wang, J. (2009). Carbon paste
electrodes in facts, numbers, and notes: A review on the occasion of the 50-years
jubilee of carbon paste in electrochemistry and electroanalysis. Electroanalysis,
21(1), 7–28.
Syahida, N., Rais, M., Isa, I., Hashim, N., Saidin, M. I., Yazid, S. N. A. M., et al. (2019).
Simultaneously determination of bisphenol A and uric acid by dichlorophenoxy)
propionate paste electrode. International Journal of Electrochemical Science, 14,
7911–7924.
Taei, M., Salavati, H., Hasanpour, F., Habibollahi, S., & Baghlani, H. (2016).
Simultaneous determination of ascorbic acid, acetaminophen and codeine based
on multi-walled carbon nanotubes modified magnetic nanoparticles paste
electrode. Materials Science & Engineering C, 69, 1–11.
Tanida, T., Warita, K., Ishihara, K., Fukui, S., Mitsuhashi, T., Sugawara, T., et al.
(2009). Fetal and neonatal exposure to three typical environmental chemicals with
different mechanisms of action: Mixed exposure to phenol, phthalate, and dioxin
cancels the effects of sole exposure on mouse midbrain dopaminergic nuclei.
Toxicology Letters, 189, 40–47.
Tehrani, R. M. A., & Ab Ghani, S. (2012). MWCNT-ruthenium oxide composite paste
electrode as non-enzymatic glucose sensor. Biosensors and Bioelectronics, 38(1),
278–283.
Teixeira, M. A., Mageste, A. B., Dias, A., Virtuoso, L. S., & Siqueira, K. P. F. (2018).
Layered double hydroxides for remediation of industrial wastewater containing
manganese and fluoride. Journal of Cleaner Production, 171, 275–284.
Telegdi, J., Shaban, A., & Vastag, G. (2018). Biocorrosion-Steel. In Encyclopedia of
Interfacial Chemistry (pp. 28–42). Elsevier Inc.
Temerk, Y., & Ibrahim, H. (2015). A new sensor based on In doped CeO2 nanoparticles
modified glassy carbon paste electrode for sensitive determination of uric acid in
biological fluid. Sensors & Actuators B: Chemical. 224, 868-877.
Thayer, K., Doerge, D. R., Hunt, D., Schurman, S. H., Twaddle, N. C., Churchwell, M.
I., et al. (2018). Pharmacokinetics of bisphenol A in humans following a single
oral administration pharmacokinetics of bisphenol A in humans following a single
oral administration. Environment International, 83(6), 107–115.
Theiss, F. L., Ayoko, G. A., & Frost, R. L. (2013). Removal of boron species by layered
double hydroxides: A review. Journal of Colloid and Interface Science, 402, 114–
121.
Therias, S., & Mousty, C. (1995). Electrodes modified with synthetic anionic clays.
Applied Clay Science, 10, 147–162.
Tian, J., Qu, J., Wan, L., Zhang, Q., & Gao, H. (2018). Boron removal using Li-Al-OH
layered double hydroxide prepared by one-step mechanochemical approach.
doi:10.20944/preprints201811.0477.v1.
Tiwari, J. N., Vij, V., Kemp, K. C., & Kim, K. S. (2015). Engineered carbonnanomaterial
based electrochemical sensors for biomolecules. American Chemical
Society, 10(1), 46–80.
Tonelli, D., Scavetta, E., & Giorgetti, M. (2013). Layered-double-hydroxide-modified
electrodes: electroanalytical applications. Analytical and Bioanalytical Chemistry,
405(2), 603–614.
Tsierkezos, N. G., & Ritter, U. (2012). Influence of concentration of supporting
electrolyte on electrochemistry of redox systems on multi-walled carbon
nanotubes. Physics and Chemistry of Liquids, 50(5), 661–668.
Karabiberoglu, S. U. (2019). Sensitive voltammetric determination of bisphenol A
based on a glassy carbon electrode modified with copper oxide-zinc oxide
decorated on graphene oxide. Electroanalysis, 31(1), 91–102.
Vandenberg, L. N., Hauser, R., Marcus, M., Olea, N., & Welshons, W. V. (2007).
Human exposure to bisphenol A (BPA). Reproductive Toxicology, 24(2), 139–
177.
Verma, D., Chauhan, D., Das Mukherjee, M., Ranjan, K. R., Yadav, A. K., & Solanki,
P. R. (2021). Development of MWCNT decorated with green synthesized AgNpsbased
electrochemical sensor for highly sensitive detection of BPA. Journal of
Applied Electrochemistry. doi: 10.1007/s10800-020-01511-3.
Vicente-mart, Y., Caravaca, M., & Soto-Meca, A. (2020). Determination of very low
concentration of bisphenol A in toys and baby pacifiers using dispersive liquid–
liquid microextraction by in situ ionic liquid formation and high- performance
liquid chromatography. Pharmaceuticals, 13, 301–313.
Vytras, K., Švancara, I., & Metelka, R. (2009). Carbon paste electrodes in
electroanalytical chemistry. Journal of the Serbian Chemical Society, 74(10),
1021–1033.
Wang, B., Zhang, H., Evans, D. G., & Duan, X. (2005). Surface modification of layered
double hydroxides and incorporation of hydrophobic organic compounds.
Materials Chemistry and Physics, 92, 190–196.
Wang, C., Liu, L., Xue, H., Hu, X., & Wang, G. (2013). Fabrication of nanoelectrode
ensembles formed via PAN-co-PAA self-assembly and selective voltammetric
detection of uric acid in biologic samples. Sensors and Actuators B: Chemical,
181, 194–201.
Wang, J. (2000). Potentiometry. In Analytical Electrochemistry (2nd ed., Vol. 3, pp.
140–170). Wiley-VCH.
Wang, J. (2006). Analytical Electrochemistry (3rd ed.). New York: Wiley-VCH.
Wang, J., Fang, X., Zhang, Y., Cui, X., Zhao, H., Li, X., & Li, Z. (2018). A simple and
rapid colorimetric probe for uric acid detection based on redox reaction of
3,3?,5,5?-tetramethylbenzidine with HAuCl4. Colloids and Surfaces A, 555, 565–
571.
Wang, X., You, Z., Sha, H., Cheng, Y., Zhu, H., & Sun, W. (2014). Sensitive
electrochemical detection of dopamine with a DNA/graphene bi-layer modified
carbon ionic liquid electrode. Talanta, 128, 373–378.
Wang, Y., Peng, W., Liu, L., Tang, M., Gao, F., & Li, M. (2011). Enhanced
conductivity of a glassy carbon electrode modified with a graphene-doped film of
layered double hydroxides for selectively sensing of dopamine. Microchimica
Acta, 173, 41–46.
Wardani, N. I., Isa, I. M., Hashim, N., & Ghani, S. A. (2014). Zinc layered hydroxide-
2(3-chlorophenoxy)propionate modified multi-walled carbon nanotubes paste
electrode for the determination of nano-molar levels copper(II). Sensors and
Actuators B: Chemical, 198, 243–248.
Welshons, W. V, Nagel, S. C., & Saal, F. S. (2006). Large effects from small exposures
. III . Endocrine mechanisms mediating effects of bisphenol A at levels of human
exposure. Endocrinology, 147(6), S56–S69.
Westbrook, A., & Frank, M. (2018). Dopamine and proximity in motivation and
cognitive control. Current Opinion in Behavioral Sciences, 22, 28–34.
Wijeratne, K. (2018). Conducting Polymer Electrodes for Thermogalvanic Cells.
Linköping University, Sweden.
Winiarski, J. P., Rampanelli, R., Bassani, J. C., Mezalira, D. Z., & Jost, C. L. (2020).
Multi-walled carbon nanotubes/nickel hydroxide composite applied as
electrochemical sensor for folic acid (vitamin B9) in food samples. Journal of
Food Composition and Analysis, 92, 103511.
Xin, X., Sun, S., Li, H., Wang, M., & Jia, R. (2015). Chemical Electrochemical
bisphenol A sensor based on core–shell multiwalled carbon nanotubes/graphene
oxide nanoribbons. Sensors & Actuators B: Chemical, 209, 275–280.
Xu, Y., Liu, X., Ding, Y., Luo, L., Wang, Y., Zhang, Y., & Xu, Y. (2011). Preparation
and electrochemical investigation of a nano-structured material Ni2+/MgFe layered
double hydroxide as a glucose biosensor. Applied Clay Science, 52(3), 322–327.
Xu, Y., Shan, Y., Cong, H., Shen, Y., & Yu, B. (2018). Advanced carbon-based
nanoplatforms combining drug delivery and thermal therapy for cancer treatment.
Current Pharmaceutical Design, 24(34), 4060-4076.
Xu, Z., Fan, J., Zheng, S., Ma, F., & Yin, D. (2009). On the adsorption of tetracycline
by calcined magnesium-aluminum hydrotalcites. Journal of Environmental
Quality, 38(3), 1302–1310.
Xu, Z., Wu, Q., Duan, Y., Yang, M., Ou, M., & Xu, X. (2017). Development of a novel
spectrophotometric method based on diazotization-coupling reaction for
determination of bisphenol A. Journal of the Brazilian Chemical Society, 28(8),
1475–1482.
Yan, Q., Zhi, N., Yang, L., Xu, G., Feng, Q., Zhang, Q., & Sun, S. (2020). A highly
sensitive uric acid electrochemical biosensor based on a nano-cube cuprous
oxide/ferrocene/uricase modified glassy carbon electrode. Scientific Reports,
10(1), 10607.
Yang, Y., Zhang, H., Huang, C., & Jia, N. (2016). MWCNTs-PEI composites-based
electrochemical sensor for sensitive detection of bisphenol A. Sensors & Actuators
B: Chemical, 235, 408–413.
Yao, Y., Wu, H., & Ping, J. (2018). Simultaneous determination of Cd(II) and Pb(II)
ions in honey and milk samples using a single-walled carbon nanohorns modified
screen-printed electrochemical sensor. Food Chemistry, 274, 8-15.
Yin, H., Zhou, Y., Ai, S., Han, R., Tang, T. & Zhu, L. (2010). Electrochemical behavior
of bishpenol A at glassy carbon electrode modified with gold nanoparticles, silk
fibroin, and PAMAM dendrimers. Microchimica Acra, 170, 99-105.
Yin, H., Cui, L., Ai, S., Fan, H., & Zhu, L. (2010). Electrochemical determination of
bisphenol A at Mg-Al-CO3 layered double hydroxide modified glassy carbon
electrode. Electrochimica Acta, 55(3), 603–610.
Yin, H., Shang, K., Meng, X., & Ai, S. (2011). Voltammetric sensing of paracetamol,
dopamine and 4-aminophenol at a glassy carbon electrode coated with gold
nanoparticles and an organophillic layered double hydroxide. Microchimica Acta,
175, 39–46.
Yin, H., Zhou, Y., Cui, L., Liu, X., Ai, S., & Zhu, L. (2011). Electrochemical oxidation
behavior of bisphenol A at surfactant/layered double hydroxide modified glassy
carbon electrode and its determination. Journal of Solid State Electrochemistry,
15(1), 167–173.
Yomthiangthae, P., Kondo, T., Chailapakul, O., & Siangproh, W. (2020). The effects
of the supporting electrolyte on the simultaneous determination of vitamin B2,
vitamin B6, and vitamin C using a modification-free screen-printed carbon
electrode. New Journal of Chemistry, 44(29), 12603–12612.
Yoon, E., Babar, A., Choudhary, M., Kutner, M., & Pyrsopoulos, N. (2016).
Acetaminophen-induced hepatotoxicity: A comprehensive update. Journal of
Clinical and Translational Hepatology, 4, 131–142.
Zeng, S., Xu, X., Wang, S., Gong, Q., Liu, R., & Yu, Y. (2013). Sand flower layered
double hydroxides synthesized by co-precipitation for CO2 capture: Morphology
evolution mechanism , agitation effect and stability. Materials Chemistry and
Physics, 140(1), 159–167.
Zhan, T., Song, Y., Li, X., & Hou, W. (2016). Electrochemical sensor for bisphenol A
based on ionic liquid functionalized Zn-Al layered double hydroxide modified
electrode. Materials Science and Engineering C, 64, 354–361.
Zhan, T., Song, Y., Tan, Z., & Hou, W. (2017). Electrochemical bisphenol A sensor
based on exfoliated Ni2Al-layered double hydroxide nanosheets modified
electrode. Sensors and Actuators B: Chemical, 238, 962–971.
Zhang, B., Huang, D., Xu, X., Alemu, G., Zhang, Y., Zhan, F., et al. (2013).
Simultaneous electrochemical determination of ascorbic acid, dopamine and uric
acid with helical carbon nanotubes. Electrochimica Acta, 91, 261–266.
Zhang, L., & Lin, X. (2001). Covalent modification of glassy carbon electrode with
glutamic acid for simultaneous determination of uric acid and ascorbic acid.
Analyst, 126(3), 367–370.
Zhang, S., Fu, Y., Sheng, Q., & Zheng, J. (2017). Nickel-cobalt double hydroxide
nanosheets wrapped amorphous Ni(OH)2 nanoboxes: Development of dopamine
sensor with enhanced electrochemical properties. New Journal of Chemistry,
41(21), 13076–13084.
Zhang, S., Yan, Y., Wang, W., Gu, X., Li, H., Li, J., & Sun, J. (2017). Intercalation of
phosphotungstic acid into layered double hydroxides by reconstruction method
and its application in intumescent flame retardant poly (lactic acid) composites.
Polymer Degradation and Stability, 147, 142–150.
Zhang, X., Cui, Y., Lv, Z., Li, M., Ma, S., Cui, Z., & Kong, Q. (2011). Carbon
nanotubes, conductive carbon black and graphite powder based paste electrodes.
International Journal of Electrochemical Science, 6, 6063–6073.
Zhao, Q., Gan, Z., & Zhuang, Q. (2002). Electrochemical sensors based on carbon
nanotubes. Electroanalysis, 14(23), 1609–1613.
Zhou, W., Wang, C., Liu, Y., Zhang, W., & Chen, Z. (2017). Layered double
hydroxides based ion exchange extraction for high sensitive analysis of nonsteroidal
anti-inflammatory drugs. Journal of Chromatography A, 1515, 23–29.
Zhou, Y., Yan, H., Xie, Q., Huang, S., Liu, J., Li, Z., et al. (2013). Simultaneous
analysis of dopamine and homovanillic acid by high-performance liquid
chromatography with wall-jet/thin-layer electrochemical detection. Royal Society
of Chemistry, 138, 7246–7253.
Zhu, Z., Qu, L., Guo, Y., Zeng, Y., Sun, W., & Huang, X. (2010). Electrochemical
detection of dopamine on a Ni/Al layered double hydroxide modified carbon ionic
liquid electrode. Sensors and Actuators B: Chemical, 151(1), 146–152.